People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Rozsypalová, Iva
Brno University of Technology
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2021Strength characteristics of concrete exposed to the elevated temperatures according to the temperature-time curve ISO 834citations
- 2021Influence of rock inclusion composition on the fracture response of cement-based composite specimenscitations
- 2021Effects of elevated temperature on the behaviour of concrete beams reinforced with fiber reinforced polymerscitations
- 2019Properties of concrete intended for further testing measured by the Impact-Echo and the ultrasonic pulse methodcitations
Places of action
Organizations | Location | People |
---|
conferencepaper
Strength characteristics of concrete exposed to the elevated temperatures according to the temperature-time curve ISO 834
Abstract
While exposed to high temperatures caused by fire, the concrete undergoes a sequence of physical and chemical structure changes causing a mechanical degradation. This paper concerns an experimental strength determination of a temperature stressed concrete. The concrete was temperature loaded according to temperature-time curve ISO 834 and left on a top temperature level for 60 minutes afterwards. This temperature heating rise is in accordance with a common fire expansion in a structure. The concrete panels sized 150 × 1300 × 2300 mm were temperature loaded up to 550, 600, 800 a 1000 °C in a horizontal position in gas furnace for fire testing of structure elements in research Centre AdMaS. The temperatures of the gas in the furnace and the panel was measured during the whole experiment by using the thermocouples. After the fire test, the specimens were drilled out using a 100 mm diameter core drill. The compressive strength and splitting tensile strength tests were made and the results were compared to the reference specimen’s test results. The objective results of a commonly used strength class concrete loaded by elevated temperature corresponding to the real fire exposure differ common linear heat exposure test results and are considered being very valuable.