People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Griffith, Michael
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (5/5 displayed)
- 2017Two-way cavity clay brick masonry walls tested in-situ
- 2016Flexural behaviour of FRP strengthened brick cavity walls
- 2014In situ out-of-plane testing of as-built and retrofitted unreinforced masonry wallscitations
- 2014Detailed seismic assessment and improvement procedure for vintage flexible timber diaphragms
- 2010In-situ testing of a residential unreinforced masonry building located in New Zealand
Places of action
Organizations | Location | People |
---|
document
Two-way cavity clay brick masonry walls tested in-situ
Abstract
This research is aimed at producing experimental data in relation to the out-of-plane behavior of two-way spanning unreinforced clay brick cavity walls, which is currently a significant area of shortcoming in seismic assessment of masonry buildings. Destructive out-of-plane airbag tests were conducted on a total of 10 two-way spanning walls (6 cavity, 4 solid) and 1 vertically spanning cavity wall in 3 low-rise properties located in Darlington, South Australia. The load was applied on the face of one leaf and the lateral displacements of both wall leaves were measured. Companion material testing was done both in-situ and in laboratory to aid in the calculation of theoretical wall strength. It was observed that the as-built cavity wall ties possessed significant compressive strength that maintained the cavity by promoting two-way out-of-plane mechanism in the unloaded wall leaf, i.e. the wall ties strength often exceeded single-leaf two-way spanning wall strength. Calculations showed that the strength of cavity walls as a whole exceeded the theoretical calculations made based on an idealized method available in seismic codes. The underestimation of the wall strength by codes and analytical studies were attributed to factors that included ignoring wall rendering and potentially conservatisms associated with the formulation of the methods.