Topics
Publications (34/34 displayed)
- 2024Effect of accelerated carbonation on electrical resistivity and microstructure of clinker-slag-limestone cement based concretescitations
- 2024Design and validation of a multi-electrode embedded capacitive sensor to monitor the electromagnetic properties in concrete structurescitations
- 2023Temperature Effect on Electrical Resistivity Measurement Using an Embedded Sensor to Estimate Concrete Water Contentcitations
- 2023Calibration process of a capacitive probe for monitoring of reinforced concrete nuclear structures
- 2022Temperature Effect on Electrical Resistivity Measurement Using an Embedded Sensor to Estimate Concrete Water Contentcitations
- 2022Temperature Effect on Electrical Resistivity Measurement Using an Embedded Sensor to Estimate Concrete Water Contentcitations
- 2022Calibration procedure for the development of an embedded capacitive sensor
- 2022Non-destructive measurements for the evaluation of the air permeability of concrete structurescitations
- 2021Joint inversion of electromagnetic measurements for the determination of water saturation profiles in concrete structurescitations
- 2020Complex dielectric permittivity database of porous limestone (tuffeau)
- 2020Towards the Determination of Chloride Profiles by means of Resistivity Measurements in Reinforced Concrete
- 2020Towards the Determination of Chloride Profiles by means of Resistivity Measurements in Reinforced Concrete
- 2020A Joint Inversion Approach of Capacitive and Resistive Measurements for the Estimation of Water Saturation Profiles in Concrete Structurescitations
- 2018Determining chloride content profiles in concrete using an electrical resistivity tomography devicecitations
- 2018Design and implementation of embedded sensors based on electrical resistivity to determine water content profiles in thick concrete structures
- 20184 - Electrical Methodscitations
- 2018Influence of Concrete Carbonation on Electromagnetic Permittivity Measured by GPR and Capacitive Techniquescitations
- 2017Development of a multi-linear quadratic experimental design for the EM characterization of concretes in the radar frequency-bandcitations
- 2017Effect of concrete carbonation on GPR and capacitive measurements
- 2017Effect of water and chloride contents and carbonation on the electromagnetic characterization of concretes on the GPR frequency band through designs of experimentcitations
- 2017Determination of concrete water content by coupling electromagnetic methods: Coaxial/cylindrical transition line with capacitive probescitations
- 2016EM characterization of concretes focused on water and chloride content in the frame of multi-linear experimental designscitations
- 2016Using machine learning algorithms to link volumetric water content to complex dielectric permittivity in a wide (33-2000 MHz) frequency band for hydraulic concretescitations
- 2016Determining the permittivity profile inside reinforced concrete using capacitive probescitations
- 2015Use of electromagnetic non-destructive techniques for monitoring the chloride ingress into concretecitations
- 2015Electromagnetic non-destructive evaluation techniques for the monitoring of water and chloride ingress into concrete: a comparative studycitations
- 2015Application of electromagnetic waves propagating in multi-layered waveguide to monitor chloride ingress into concrete
- 2014Identification of inhomogeneous concrete cover by non-contact ultrasonic method
- 2013Acoustic techniques for concrete evaluation: improvements, comparisons and consistencycitations
- 2013Development of a multi-ring resistivity cell and multi-electrode resistivity probe for investigation of covercitations
- 2012Complex permittivity frequency variations from multi-offset GPR data: hydraulic concrete characterizationcitations
- 2012Development of an ultrasonic experimental device to characterise concrete for structural repaircitations
- 2011On variants of the frequency power law for the electromagnetic characterization of hydraulic concretecitations
- 2009Determination of the bulk elastic moduli of various concrete by resonance frequency analysis of slabs submitted to degradations
Places of action
Organizations | Location | People |
---|
document
Towards the Determination of Chloride Profiles by means of Resistivity Measurements in Reinforced Concrete
Abstract
Reinforced concrete (RC) structures, such wharfs or floating structures, are submitted to chloride ingress which can lead to rebar corrosion. Before the corrosion initiation, in a preventive point of view, engineers can be interested in non-destructive evaluation and inspection methods. In that way, electrical resistivity tomography is a promising tool to access to resistivity profiles then to chloride profiles in real RC structures in the future. We would like to present herein the advances in the necessary research developments to reach this goal, i.e. the resistivity profiles obtained in reinforced concrete slabs submitted to chloride ingress. The 4 slab dimensions are 90x70x13 cm. The specimens are cured, dried during 9 months then submitted to salted water imbibition during 4 months. Electrical resistivity tomography measurements are performed at short terms during 1 week of imbibition. The monitoring show that several phenomena influence the resistivity profiles such as the penetration of water and chloride ions. Meanwhile, steel rebar effect can be considered thus eliminated from electrical resistivity profiles following the method developed by (Alhajj et al. 2019).