People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Chagnon, Grégory
Université Grenoble Alpes
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (28/28 displayed)
- 2020Anisotropy and Clausius-Clapeyron relation for forward and reverse stress-induced martensitic transformations in polycrystalline NiTi thin walled tubescitations
- 2020A comprehensive thermo-viscoelastic experimental investigation of Ecoflex polymercitations
- 2019Strain Gauges Based 3D Shape Monitoring of Beam Structures Using Finite Width Gauge Modelcitations
- 2019Characterizing Transformation Phenomena and Elastic Moduli of Austenite and Oriented Martensite of Superelastic Thin NiTi Wire through Isothermal Dynamic Mechanical Analysiscitations
- 2018Anisotropy and temperature dependence of superelastic behavior of NiTi shape memory alloy thin walled tubes
- 2018Mechanical and radiological behavior of a bioresorbable polymer during in vivo degradation. An in vivo rat study to develop an Internal biliary stent to reduce biliary complications after liver transplantation
- 2018Geometry-based model for U-shaped strain gauges on medical needles
- 2017Anisotropic tensile behavior of NiTi Tubes and its dependence on temperature experimental results
- 2016Modelling of mechanical properties of a PLA-b-PEG-b-PLA biodegradable triblock copolymer during hydrolytic degradation
- 2016Anisotropic thermomechanical properties of a superelastic Nickel-Titane thin tube
- 2015Radiopaque poly(ε-caprolactone) as additive for X-ray imaging of temporary implantable medical devicescitations
- 2015Study of electropulse heat treatment of cold worked NiTi wire: From uniform to localised tensile behaviourcitations
- 2015Mechanically-architectured silicone elastomer membranes for biomedical applications
- 2014A conical mandrel tube drawing test designed to assess failure criteriacitations
- 2014Mechanical characterization and comparison of different NiTi/silicone rubber interfacescitations
- 2013Design of specific experimental tests to evaluate formability prediction of cold drawing CoCr Tubes
- 2012Mechanical behaviour of architectured NiTi materials in complex loading
- 2012Mechanical behaviour of architectured NiTi materials in complex loading
- 2012Experiments and modeling of smart silicone elastomer membranes reinforced with shaped NiTi textiles
- 2011Simulation of Drawing of Small Stainless Steel Platinum Medical Tubes-Influence of the Tool Parameters on the Forming Limitcitations
- 2009Thermomechanical modelling of cold drawing processes of small diameter tubes
- 2007Tube Drawing Process Modelling By A Finite Element Analysis
- 2007Tube Drawing Process Modelling By A Finite Element Analysis
- 2007Modélisation de l'étirage à froid de tubes par analyse éléments-finis
- 2004Theoretical and numerical limitations for the simulation of crack propagation in natural rubber components
- 2003Theoretical and numerical limitations for the simulation of crack propagation in natural rubber components
- 2003Crack initiation in filled natural rubber: experimental database and macroscopic observations
- 2002Influence of the loading conditions on fatigue properties for filled elastomers
Places of action
Organizations | Location | People |
---|
conferencepaper
Influence of the loading conditions on fatigue properties for filled elastomers
Abstract
International audience ; Fatigue characterisation of elastomers is an essential prerequisite of new car project schedules imposed by carmakers. Consequently, durability prediction softwares are needed to reduce the time allowed to design elastomeric parts. Until now, the only theoretical variable used to predict duration life is the tearing energy proposed by Rivlin and Thomas. Classically, fatigue properties are determined using plane stress experiments (trousers or pure shear samples for example) under simple loading conditions. In the present paper, a brief bibliographical review presents the limitations of this approach and the need of more complex loading conditions is emphasised. Then, a new simple shear sample is proposed to simplify the treatment of experimental results, said the calculation of the tearing energy, under complex loading conditions. The test sample is initially notched and is submitted to controlled displacement loading conditions. The procedure adopted to analyse the results is presented. Assuming that the tearing energy and the crack growth rate remain constant during the test, they can be easily calculated using both the decreasing stiffness of the sample during the test and a FE model. Note that no complex system, such as video recording, is necessary to measure the crack length. Then, experimental results are reported. Both filled crystallising and non-crystallising elastomers are studied in order to highlight the influence of the testing temperature and of the imposed displacement ratio (i.e.: minimum/maximum displacement) on the fatigue crack growth rate law. This fatigue crack growth rate law obtained agrees well with previously published papers. Furthermore, other complex tests are in progress to determine the influence of the Mullins stress-softening on fatigue properties. Finally, in regards with these results, it is demonstrated that the tearing energy is not a sufficient variable to completely characterise the fatigue life of elastomers.