People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Gill, H. S.
University of Bath
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (18/18 displayed)
- 2024Experiments and numerical modelling of secondary flows of blood and shear-thinning blood analogue fluids in rotating domainscitations
- 2024Auxetic fixation devices can achieve superior pullout performances compared to standard fixation conceptscitations
- 2021Properties of PMMA end cap holders affect FE stiffness predictions of vertebral specimens
- 20213D Printed Medical Grade Ti-6Al-4V Osteosynthesis Devices Meet the Requirements for Tensile Strength, Bending, Fatigue and Biocompatibility
- 2019Evaluating strength of 3D printed screw threads for patient-specific osteosynthesis plates
- 2019Evaluation of optimised cervical spine viscoelastic elements for sport injury analysis
- 2018The effect of plate design, bridging span, and fracture healing on the performance of high tibial osteotomy plates – an experimental and finite element study.citations
- 2017Validated cemented socket model for optimising acetabular fixation
- 2017Effect of absorbed fatty acids on physical properties of ultra-high molecular weight polyethylene
- 2017Use of contrast agents on polymeric materials
- 2016A Python Package to Assign Material Properties of Bone to Finite Element Models from within Abaqus Software
- 2016An open source software tool to assign the material properties of bone for ABAQUS finite element simulationscitations
- 2016A validated specimen specific finite element model of vertebral body failure
- 2016Variations in Cortical Thickness of Composite Femur Test Specimens
- 2015Tibial Fracture after Unicompartmental Knee Replacement: The Importance of Surgical Cut Accuracy
- 2014Classification of retinal ganglion cells in the southern hemisphere lamprey Geotria australis (Cyclostomata)citations
- 2014Effect of Q-switched laser surface texturing of titanium on osteoblast cell response
- 2013Fracture of mobile unicompartmental knee bearingscitations
Places of action
Organizations | Location | People |
---|
document
Use of contrast agents on polymeric materials
Abstract
Polymers are one of the fastest growing areas in biomaterials, and are used in a wide range of medical applications. One the limitations of many medical polymers is low visibility in X-ray images. X-ray imaging can be used to assess implant positioning and function after an operation and it is also possible to use X-ray fluoroscopy to aid implant positioning during surgery. This presentation explores the current approaches used to enhance the radiopacity in polymers, focusing on two implantable polymeric materials; poly methyl methacrylate (PMMA), and ultra-high molecular weight polyethylene (UHMWPE). These polymers are used clinically for long term implant applications, such as hip and knee replacements, where they are in direct contact with biological tissues and subjected to challenging mechanical and chemical conditions.