People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
González Madruga, Daniel
Technical University of Denmark
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (6/6 displayed)
- 2018Post moulding thermal characterization of polymer components
- 2017Monitoring of the thermal deformations on polymer parts using a vision system
- 2016The influence of humidity on accuracy length measurement on polymer parts
- 2016Length determination on industrial polymer parts from measurement performed under transient temperature conditions
- 2015Defining Allowable Physical Property Variations for High Accurate Measurements on Polymer Parts.citations
- 2015Dimensional measurements with submicrometer uncertainty in production environment
Places of action
Organizations | Location | People |
---|
document
The influence of humidity on accuracy length measurement on polymer parts
Abstract
The work deals with an experimental study of the influence of humidity on accurate length measurements on ABS parts. Polymer parts absorb water from the ambient until they reach hygroscopic equilibrium. Water content causes an expansion of the polymer part. The relationship between the water content and this expansion has been barely studied, especially from a metrology point of view including its contribution to the measurement uncertainty. The experimental set-up includes a humidity chamber, an invar fixture with 8 inductive probes and a scale. The humidity chamber was used to create the experiment ambient conditions. The invar fixture with the inductive probes, with a resolution of 0.1 μm, allows length measurement on 8 ABS parts at the same time. The scale was used to collect the water content variation during the experiment with a resolution of 0.1 mg. The length and weight of the ABS parts were measured at 5 levels of relative humidity from 50 %RH to 90 %RH, and constant temperature, 20 ±0.2˚C. Water content equilibrium with the ambient was achieved at each level by acclimatization of the parts for 24 hours. An average length variation over the humidity range of 15 μm was found. A condition specific coefficient of moisture expansion of 69±4 μm/(Δ of weight in mg) was estimated.