People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Taylor, Susan
Queen's University Belfast
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (21/21 displayed)
- 2023Experimental and numerical investigation of compressive membrane action in GFRP-reinforced concrete slabscitations
- 2023Characterisation of hemp shiv and its effect on the compressive strength of hemp concretecitations
- 2022Effect of the Treatments of the Surface on Mechanical Performance of Concrete Containing Chemical Admixtures
- 2022Factorial design modelling of cement grout containing dolomitic quarry dust powdercitations
- 2022Assessment of the influence of the type of filler materials on the properties of cement groutscitations
- 2020Experimental Investigation of Strain Sensitivity for Surface Bonded Fibre Optic Sensorscitations
- 2019Recycling ceramic waste powder: effects its grain-size distribution on fresh and hardened properties of cement pastes/mortars formulated from SCC mixescitations
- 2017The influence of arching action on BFRP reinforced SCC deck slabs in Thompson bridge
- 2016Experimental Study of Interfacial Stress Distribution of Bonded-in BFRP Rod Glulam Joints Using Fibre Optic Sensors (FOS)citations
- 2016Glued-in basalt frp rods as moment connections in box section frames
- 2016Effect of waste ceramic powder on strength development characteristics of cement based mortars
- 2015Nový přístup k určení optimální dávky superplatifikátorůa jejich kompatibility s cementovými materiály
- 2015Post-tensioning glulam timber beams with basalt FRP tendonscitations
- 2014POST-TENSIONING OF TIMBER BEAMS WITH BASALT FIBRE REINFORCED POLYMER
- 2014Influence of embedded length on strength of BFRP rods bonded parallel to the grain in low grade timber by pullout-bending tests
- 2014Post-tensioning of glulam timber with steel tendonscitations
- 2014Development of Novel Post-Tensioned Glulam Timber Composites
- 2014Compability of Superplasticizers with Cementitious Materials
- 2012Influence of the type of coarse lightweight aggregate on properties of Semi-Lightweight Self-Consolidating Concretecitations
- 2009Monitoring of Corrosion in Structural Reinforcing Bars: performance comparison using in-situ fibre optic and electric wire strain gauge systemscitations
- 2009In situ cross-calibration of in-fibre Bragg Grating and Electrical Resistance Strain Gauges for structural monitoring using an extensometercitations
Places of action
Organizations | Location | People |
---|
document
Glued-in basalt frp rods as moment connections in box section frames
Abstract
<p>An experimental programme is presented that investigates the application of glued-in rods as moment connections in a post and beam connection. Nine partial portal frames were constructed of box sections with a beam depth of 600mm. The box sections were constructed of sawn timber flanges with orientated strand board and birch plywood webs. 12mm diameter basalt fibre reinforced polymer rods were used to connect the elements with a constant embedded length of 23·d<sub>r</sub> (280mm) and glueline thickness of 0.125·d<sub>r</sub> (2mm). Specimens with 2 no. and 3 no. rods were tested to structural failure. Specimens constructed from box sections with OSB webs reached their maximum capacity and then failed via elemental failure prior to the capacity of the connection being reached. Specimens with plywood webs were considerably stronger exhibiting failure in the connection. All the test specimens did exhibit significant deflection which would result in a lower serviceability limit state failure.</p>