People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Beillas, Philippe
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2016Abdominal wall muscle elasticity and abdomen local stiffness on healthy volunteers during various physiological activitiescitations
- 2015Effects of pressure on the shear modulus, mass and thickness of the perfused porcine kidneycitations
- 2013Effects of storage temperature on the mechanical properties of porcine kidney estimated using Shear Wave Elastographycitations
- 2012Repeatability of a protocol to evaluate the effect of storage on the mechanical properties of the kidney in-vitro
Places of action
Organizations | Location | People |
---|
conferencepaper
Repeatability of a protocol to evaluate the effect of storage on the mechanical properties of the kidney in-vitro
Abstract
International audience ; In biomechanical testing protocols of soft tissue, specimens may have to undergo freezing or other conservation methods, which could affect their mechanical properties. In order to evaluate the effects of conservation techniques, an experimental protocol based on shear wave elastography - which provides an assessment of shear modulus (μ) – was developed and applied to porcine kidneys. First, the organ is pinned onto a polystyrene plate. Then the plate then used to position the organ with respect to an ultrasound probe. This study provides an estimation of the repeatability of μ after repositioning a single kidney, and evaluates the effects of storing 8 fresh kidneys at room temperature for two days. μ were computed rectangular windows centred on the image and moving along the organ depth. When repositioning the organ, μ was more repeatable in the cortex near the capsule than in the central regions of the organ. These regions were also more inhomogeneous and imaging was not always possible due to ultrasound penetration issues. The cortex near the capsule was softer than the central regions including pyramids (e.g. 6.1±2.4kPa at 10% depth vs. 9.3±3.5kPa at 30% depth, n=8). Storage for two days had no significant effect on these values (p>0.25).