People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Soballe, K.
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (3/3 displayed)
- 2013No positive effect of Acid etching or plasma cleaning on osseointegration of titanium implants in a canine femoral condyle press-fit modelcitations
- 2011The combined effect of parathyroid hormone and bone graft on implant fixationcitations
- 2000Osteogenic protein 1 device stimulates bone healing to hydroxyapaptite-coated and titanium implants
Places of action
Organizations | Location | People |
---|
article
Osteogenic protein 1 device stimulates bone healing to hydroxyapaptite-coated and titanium implants
Abstract
This study evaluated the effects of osteogenic protein 1 (OP-1) placed in a gap around uncoated and hydroxyapatite (HA)-coated implants. Unloaded cylindrical titanium alloy implants were inserted in the femoral condyles of 16 skeletally mature dogs surrounded by a 3-mm gap. The gap around the implants was filled with 325 microg OP-1 in 130 mg bovine collagen type I as carrier (OP-1 device) or collagen carrier alone or left empty. All groups were tested with both HA-coated and uncoated implants, and the animals were sacrificed after 6 weeks. Implant fixation was determined by push-out test. Bone ongrowth and bone formation were evaluated by quantitative histomorphometry. OP-1 device enhanced mechanical fixation of uncoated and HA-coated implants, resulting in a higher shear strength than implants with collagen matrix and control implants. Bone ingrowth and bone formation in the gap were also stimulated 3-fold for OP-1 groups when compared with empty controls, but no difference was found between OP-1 groups and collagen matrix groups. This study suggests that the OP-1 device placed in a gap around uncoated and HA-coated implants is capable of enhancing mechanical fixation and periimplant bone formation. The collagen carrier alone also enhanced bone ongrowth and fixation significantly.