Materials Map

Discover the materials research landscape. Find experts, partners, networks.

  • About
  • Privacy Policy
  • Legal Notice
  • Contact

The Materials Map is an open tool for improving networking and interdisciplinary exchange within materials research. It enables cross-database search for cooperation and network partners and discovering of the research landscape.

The dashboard provides detailed information about the selected scientist, e.g. publications. The dashboard can be filtered and shows the relationship to co-authors in different diagrams. In addition, a link is provided to find contact information.

×

Materials Map under construction

The Materials Map is still under development. In its current state, it is only based on one single data source and, thus, incomplete and contains duplicates. We are working on incorporating new open data sources like ORCID to improve the quality and the timeliness of our data. We will update Materials Map as soon as possible and kindly ask for your patience.

To Graph

1.080 Topics available

To Map

977 Locations available

693.932 PEOPLE
693.932 People People

693.932 People

Show results for 693.932 people that are selected by your search filters.

←

Page 1 of 27758

→
←

Page 1 of 0

→
PeopleLocationsStatistics
Naji, M.
  • 2
  • 13
  • 3
  • 2025
Motta, Antonella
  • 8
  • 52
  • 159
  • 2025
Aletan, Dirar
  • 1
  • 1
  • 0
  • 2025
Mohamed, Tarek
  • 1
  • 7
  • 2
  • 2025
Ertürk, Emre
  • 2
  • 3
  • 0
  • 2025
Taccardi, Nicola
  • 9
  • 81
  • 75
  • 2025
Kononenko, Denys
  • 1
  • 8
  • 2
  • 2025
Petrov, R. H.Madrid
  • 46
  • 125
  • 1k
  • 2025
Alshaaer, MazenBrussels
  • 17
  • 31
  • 172
  • 2025
Bih, L.
  • 15
  • 44
  • 145
  • 2025
Casati, R.
  • 31
  • 86
  • 661
  • 2025
Muller, Hermance
  • 1
  • 11
  • 0
  • 2025
Kočí, JanPrague
  • 28
  • 34
  • 209
  • 2025
Šuljagić, Marija
  • 10
  • 33
  • 43
  • 2025
Kalteremidou, Kalliopi-ArtemiBrussels
  • 14
  • 22
  • 158
  • 2025
Azam, Siraj
  • 1
  • 3
  • 2
  • 2025
Ospanova, Alyiya
  • 1
  • 6
  • 0
  • 2025
Blanpain, Bart
  • 568
  • 653
  • 13k
  • 2025
Ali, M. A.
  • 7
  • 75
  • 187
  • 2025
Popa, V.
  • 5
  • 12
  • 45
  • 2025
Rančić, M.
  • 2
  • 13
  • 0
  • 2025
Ollier, Nadège
  • 28
  • 75
  • 239
  • 2025
Azevedo, Nuno Monteiro
  • 4
  • 8
  • 25
  • 2025
Landes, Michael
  • 1
  • 9
  • 2
  • 2025
Rignanese, Gian-Marco
  • 15
  • 98
  • 805
  • 2025

Manero, Jose M.

  • Google
  • 3
  • 18
  • 34

in Cooperation with on an Cooperation-Score of 37%

Topics

Publications (3/3 displayed)

  • 2018Recombinant fibronectin fragment III8-10/polylactic acid hybrid nanofibers enhance the bioactivity of titanium surface5citations
  • 2017Towards the cell-instructive bactericidal substrate: exploring the combination of nanotopographical features and integrin selective synthetic ligands29citations
  • 2009Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implantscitations

Places of action

Chart of shared publication
Boix-Lemonche, Gerard
1 / 2 shared
Gugutkov, Dencho
1 / 2 shared
Guillem-Marti, Jordi
1 / 11 shared
Altankov, George
1 / 3 shared
Ginebra, Mp
2 / 289 shared
Tsimbouri, Penelope M.
1 / 1 shared
Su, Bo
1 / 29 shared
Mas-Moruno, Carlos
1 / 17 shared
Fisher, Leanne E.
1 / 1 shared
Nobbs, Angela H.
1 / 1 shared
Dalby, Matthew J.
1 / 4 shared
Fraioli, Roberta
1 / 1 shared
Neubauer, Stefanie
1 / 1 shared
Rechenmacher, Florian
1 / 1 shared
Kessler, Horst
1 / 1 shared
Gil, Francisco Javier
1 / 5 shared
Aparicio, Conrado
1 / 42 shared
Padros, Alejandro
1 / 1 shared
Chart of publication period
2018
2017
2009

Co-Authors (by relevance)

  • Boix-Lemonche, Gerard
  • Gugutkov, Dencho
  • Guillem-Marti, Jordi
  • Altankov, George
  • Ginebra, Mp
  • Tsimbouri, Penelope M.
  • Su, Bo
  • Mas-Moruno, Carlos
  • Fisher, Leanne E.
  • Nobbs, Angela H.
  • Dalby, Matthew J.
  • Fraioli, Roberta
  • Neubauer, Stefanie
  • Rechenmacher, Florian
  • Kessler, Horst
  • Gil, Francisco Javier
  • Aparicio, Conrado
  • Padros, Alejandro
OrganizationsLocationPeople

article

Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implants

  • Gil, Francisco Javier
  • Aparicio, Conrado
  • Manero, Jose M.
  • Padros, Alejandro
Abstract

<p>This study evaluated the effect of external hexagon height and commonly applied surface treatments on the fatigue life of titanium dental implants. Materials and Methods: Electropolished commercially pure titanium dental implants (seven implants per group) with three different external hexagon heights (0.6, 1.2, and 1.8 mm) and implants with the highest external hexagon height (1.8 mm) and different surface treatments (electropolishing, grit blasting with aluminium oxide, and acid etching with sulfuric acid) were tested to evaluate their mechanical fatigue life. To do so, 10-Hz triangular flexural load cycles were applied at 37°C in artificial saliva, and the number of load cycles until implant fracture was determined. Tolerances of the hexagon/abutment fit and implant surface roughness were analyzed by scanning electron microscopy and light interferometry. Transmission electron microscopy and electron diffraction analyses of titanium hydrides were performed. Results: First, the fatigue life of implants with the highest hexagon (8,683 ± 978 load cycles) was more than double that of the implants with the shortest hexagons (3,654 ± 789 load cycles) (P &lt; .02). Second, the grit-blasted implants had the longest fatigue life of the tested materials (21,393 ± 2,356 load cycles), which was significantly greater than that of the other surfaces (P &lt; .001). The compressive surface residual stresses induced when blasting titanium are responsible for this superior mechanical response. Third, precipitation of titanium hydrides in grain boundaries of titanium caused by hydrogen adsorption from the acid solution deteriorates the fatigue life of acid-etched titanium dental implants. These implants had the shortest fatigue life (P &lt; .05). Conclusions: The fatigue life of threaded root-form dental implants varies with the height of the external hexagon and/or the surface treatment of the implant. An external hexagon height of 1.8 mm and/or a blasting treatment appear to significantly increase fatigue life of dental implants.</p>

Topics
  • surface
  • grain
  • scanning electron microscopy
  • electron diffraction
  • aluminum oxide
  • aluminium
  • fatigue
  • Hydrogen
  • transmission electron microscopy
  • etching
  • precipitation
  • titanium
  • commercially pure titanium
  • interferometry