People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Rasekh, Haleh
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (7/7 displayed)
- 2019Numerical exploration of performance of cable bolts in shear loading
- 2019Rheology and workability of SCCcitations
- 2016Load transfer characteristics of plain and spiral cable bolts tested in new non rotating pull testing apparatus
- 2016A follow up to study the behaviour of cable bolts in shear: experimental study and mathematical modelling
- 2015Strength characteristics of Secura Hollow Groutable Cable Bolts
- 2015An experimental study on the contact surface area of cabled bolted strata
- 2015Strength properties of fibre glass dowels used for strata reinforcement in coal mines
Places of action
Organizations | Location | People |
---|
document
Strength properties of fibre glass dowels used for strata reinforcement in coal mines
Abstract
Glass-Reinforced Polymer (GRP) bolts, commonly known as Fibre Glass (FG) dowels are increasingly applied for strata reinforcement in mines. The most popular dowels used in coal mines are the 22 mm diameter fully threaded type. A series of tests were undertaken to evaluate various strength properties of FG dowels. These include tensile failure tests by the double-embedment method, single and double guillotine shear tests, double shear tests in concrete medium and punch shear tests. Punch shear tests were used to evaluate the dowel shear strength parallel and perpendicular to the fibre glass strands or elements direction of extrusion. The study found that the tensile strength of the 22 mm diameter fibre glass dowels was in the order of 30 t. In the shear testing, the peak shear load was influence by the encapsulation grout type and the level of fibre glass axial pre-tension. Also, there was a nearly fivefold difference in the shear strength value of fibre glass dowels tested parallel as against perpendicular to the dowel axis.