Materials Map

Discover the materials research landscape. Find experts, partners, networks.

  • About
  • Privacy Policy
  • Legal Notice
  • Contact

The Materials Map is an open tool for improving networking and interdisciplinary exchange within materials research. It enables cross-database search for cooperation and network partners and discovering of the research landscape.

The dashboard provides detailed information about the selected scientist, e.g. publications. The dashboard can be filtered and shows the relationship to co-authors in different diagrams. In addition, a link is provided to find contact information.

×

Materials Map under construction

The Materials Map is still under development. In its current state, it is only based on one single data source and, thus, incomplete and contains duplicates. We are working on incorporating new open data sources like ORCID to improve the quality and the timeliness of our data. We will update Materials Map as soon as possible and kindly ask for your patience.

To Graph

1.080 Topics available

To Map

977 Locations available

693.932 PEOPLE
693.932 People People

693.932 People

Show results for 693.932 people that are selected by your search filters.

←

Page 1 of 27758

→
←

Page 1 of 0

→
PeopleLocationsStatistics
Naji, M.
  • 2
  • 13
  • 3
  • 2025
Motta, Antonella
  • 8
  • 52
  • 159
  • 2025
Aletan, Dirar
  • 1
  • 1
  • 0
  • 2025
Mohamed, Tarek
  • 1
  • 7
  • 2
  • 2025
Ertürk, Emre
  • 2
  • 3
  • 0
  • 2025
Taccardi, Nicola
  • 9
  • 81
  • 75
  • 2025
Kononenko, Denys
  • 1
  • 8
  • 2
  • 2025
Petrov, R. H.Madrid
  • 46
  • 125
  • 1k
  • 2025
Alshaaer, MazenBrussels
  • 17
  • 31
  • 172
  • 2025
Bih, L.
  • 15
  • 44
  • 145
  • 2025
Casati, R.
  • 31
  • 86
  • 661
  • 2025
Muller, Hermance
  • 1
  • 11
  • 0
  • 2025
Kočí, JanPrague
  • 28
  • 34
  • 209
  • 2025
Šuljagić, Marija
  • 10
  • 33
  • 43
  • 2025
Kalteremidou, Kalliopi-ArtemiBrussels
  • 14
  • 22
  • 158
  • 2025
Azam, Siraj
  • 1
  • 3
  • 2
  • 2025
Ospanova, Alyiya
  • 1
  • 6
  • 0
  • 2025
Blanpain, Bart
  • 568
  • 653
  • 13k
  • 2025
Ali, M. A.
  • 7
  • 75
  • 187
  • 2025
Popa, V.
  • 5
  • 12
  • 45
  • 2025
Rančić, M.
  • 2
  • 13
  • 0
  • 2025
Ollier, Nadège
  • 28
  • 75
  • 239
  • 2025
Azevedo, Nuno Monteiro
  • 4
  • 8
  • 25
  • 2025
Landes, Michael
  • 1
  • 9
  • 2
  • 2025
Rignanese, Gian-Marco
  • 15
  • 98
  • 805
  • 2025

Mathur, P.

  • Google
  • 1
  • 3
  • 7

in Cooperation with on an Cooperation-Score of 37%

Topics

Publications (1/1 displayed)

  • 2016A cost effectiveness based safety and efficacy study of resterilized intra-parenchymal catheter based intracranial pressure monitoring in developing world.7citations

Places of action

Chart of shared publication
Bisht, A.
1 / 3 shared
Dk, Gupta
1 / 1 shared
Ak, Mahapatra
1 / 1 shared
Chart of publication period
2016

Co-Authors (by relevance)

  • Bisht, A.
  • Dk, Gupta
  • Ak, Mahapatra
OrganizationsLocationPeople

article

A cost effectiveness based safety and efficacy study of resterilized intra-parenchymal catheter based intracranial pressure monitoring in developing world.

  • Bisht, A.
  • Dk, Gupta
  • Mathur, P.
  • Ak, Mahapatra
Abstract

<h4>Background</h4>The management of traumatic brain injury (TBI) aims to maintain the normal cerebral perfusion in spite of the mass lesions that may occur (haematoma, contusion, and oedema). The monitoring of the intracranial pressure (ICP) is a step in that direction. The intra-parenchymal catheters have the lowest incidence of infection compared to intra-ventricular/subdural catheters with reliable and accurate pressure recordings. The major disadvantage of the intra-parenchymal catheters is the cost, especially in developing nations.<h4>Hypothesis</h4>Resterilized intra-parenchymal strain gauge catheters can be used safely for ICP monitoring without any added risk of meningitis. The reusage of catheters can bring down the costs. Resterilized catheters/equipment have been approved for usage in cardiac usage, but such study on ICP catheters has not been carried out so far in any part of the world.<h4>Methodology</h4>A total of 100 consecutive cases of severe TBI receiving ICP monitoring at a level 1 trauma center of a developing nation were prospectively studied (34 cases had fresh catheters, and 66 had resterilized [using ethylene oxide] catheters).<h4>Observations</h4>The use of reused resterilized catheters was not associated with increased incidence of meningitis or fever (the surrogate marker for infection in this study). Also, there was concordance between the pressure recording of reused catheters and operative finding/subsequent computed tomography scans. These catheters after sterilization could be reused 2-4 times and reliably recorded the ICP (insignificant drift) with no increase in the incidence of meningitis.<h4>Conclusions</h4>Usage of resterilized intra-parenchymal ICP catheters is feasible, safe, efficacious, and cost effective and brings down the cost of monitoring significantly.

Topics
  • impedance spectroscopy
  • computed tomography scan