People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Ali, Rashid
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (3/3 displayed)
- 2023Tungsten dopant incorporation for bandgap and type engineering of perovskite crystalscitations
- 2022Effect of Bias Voltage on Adhesion and Corrosion Resistance of Titanium Nitride Coated Stainless Steel Substratecitations
- 2022Predicting Angle of Internal Friction and Cohesion of Rocks Based on Machine Learning Algorithmscitations
Places of action
Organizations | Location | People |
---|
article
Effect of Bias Voltage on Adhesion and Corrosion Resistance of Titanium Nitride Coated Stainless Steel Substrate
Abstract
<jats:p>In this work, the adhesion and corrosion resistance of TiN coating by magnetron sputtering on stainless steel substrates under different bias voltages conditions (-50 V and-100 V) was investigated. AFM was used for surface roughness and grain size analysis, XRD for phase identification, Rockwell C for adhesion and nanoindentation for hardness and elastic modulus. According to AFM the coating deposited at-100V bias had decreased surface roughness, the value decreased from 2.7 nm (for-50V sample) to 1.8 nm, this was due to an etching like process which occurs when ions with higher energies start hitting the surface. The coated samples came under HF1 adhesion parameter which is the highest class of adhesion in the model on the basis of Rockwell C adhesion test. nanoindentation hardness and elastic modulus results of-50 V and-100V were found to be 224 GPa and 182 GPa, respectively and the value of hardness, 16 GPa and 22 GPa, respectively. The corrosion behavior of TiN coatings were studied in 3.5wt. % NaCl solutions using Tafel Extrapolation, Cyclic Polarization and Open Circuit Potential. It was noted on the basis of these corrosion tests that, as bias voltage is increased, it leads to the formation of more densely packed, fine grained columnar structures with less pores, which decreases the chances of corrosion. .</jats:p>