- 2022Prediction of neonatal respiratory distress biomarker concentration by application of machine learning to mid-infrared spectracitations
- 2021The Effect of Haematocrit on Measurement of the Mid-Infrared Refractive Index of Plasma in Whole Bloodcitations
- 2018Chalcogenide glass waveguides with paper-based fluidics for mid-infrared absorption spectroscopycitations
- 2009Lightweight Mirror Developments
Places of action
Organizations | Location | People |
---|
article
Prediction of neonatal respiratory distress biomarker concentration by application of machine learning to mid-infrared spectra
Abstract
The authors of this study developed the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR–FTIR) combined with machine learning as a point-of-care (POC) diagnostic platform, considering neonatal respiratory distress syndrome (nRDS), for which no POC currently exists, as an example. nRDS can be diagnosed by a ratio of less than 2.2 of two nRDS biomarkers, lecithin and sphingomyelin (L/S ratio), and in this study, ATR–FTIR spectra were recorded from L/S ratios of between 1.0 and 3.4, which were generated using purified reagents. The calibration of principal component (PCR) and partial least squares (PLSR) regression models was performed using 155 raw baselined and second derivative spectra prior to predicting the concentration of a further 104 spectra. A three-factor PLSR model of second derivative spectra best predicted L/S ratios across the full range (R2: 0.967; MSE: 0.014). The L/S ratios from 1.0 to 3.4 were predicted with a prediction interval of +0.29, −0.37 when using a second derivative spectra PLSR model and had a mean prediction interval of +0.26, −0.34 around the L/S 2.2 region. These results support the validity of combining ATR–FTIR with machine learning to develop a point-of-care device for detecting and quantifying any biomarker with an interpretable mid-infrared spectrum.