People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Olthuis, Wouter
University of Twente
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (6/6 displayed)
- 2021Monitoring contractile cardiomyocytes via impedance using multipurpose thin film ruthenium oxide electrodescitations
- 20203D-Printing of a Lemon Battery via Fused Deposition Modelling and Electrodepositioncitations
- 2016Molecularly Imprinted Polymer-Carbon Nanotube based Cotinine sensorcitations
- 2014Modeling and simulations of the amplitude-frequency response of transmission line type resonators filled with lossy dielectric fluidscitations
- 2014Stub resonators for online monitoring early stages of corrosioncitations
- 2005Catalytic hydrogen peroxide decomposition La1-xSrxCoO3-δ perovskite oxidescitations
Places of action
Organizations | Location | People |
---|
article
Monitoring contractile cardiomyocytes via impedance using multipurpose thin film ruthenium oxide electrodes
Abstract
<p>A ruthenium oxide (RuOx) electrode was used to monitor contractile events of human pluripotent stem cells-derived cardiomyocytes (hPSC-CMs) through electrical impedance spectroscopy (EIS). Using RuOx electrodes presents an advantage over standard thin film Pt electrodes because the RuOx electrodes can also be used as electrochemical sensor for pH, O2, and nitric oxide, providing multisensory functionality with the same electrode. First, the EIS signal was validated in an optically transparent well-plate setup using Pt wire electrodes. This way, visual data could be recorded simultaneously. Frequency analyses of both EIS and the visual data revealed almost identical frequency components. This suggests both the EIS and visual data captured the similar events of the beating of (an area of) hPSC-CMs. Similar EIS measurement was then performed using the RuOx electrode, which yielded comparable signal and periodicity. This mode of operation adds to the versatility of the RuOx electrode’s use in in vitro studies.</p>