People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Feeney, Andrew
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (34/34 displayed)
- 2024High Stiffness Resin for Flexural Ultrasonic Transducers
- 2024A 3D-printable metamaterial using a magnetic membrane for tuneable acoustic resonance at low frequencies
- 2024High Frequency Air-Coupled Ultrasound Measurement with the Flexural Ultrasonic Transducer
- 2024Langevin Transducers Incorporating TPMS Lattice Front Masses
- 2024Characterisation of 3D Printable Material for an Acoustic Metamaterial Cell with Tuneable Resonancecitations
- 2023Flexural ultrasonic transducers with nonmetallic membranes
- 2023Microscale Nitinol Hardness Measurements for Engineering Adaptive Ultrasonic Devices
- 2023Fabrication and Dynamic Characterisation of a Nitinol Langevin Transducer
- 2022Enhanced Resolution Phase Transformations in a Nitinol Cymbal Ultrasonic Devicecitations
- 2021Active damping of ultrasonic receiving sensors through engineered pressure wavescitations
- 2021Higher order modal dynamics of the flexural ultrasonic transducercitations
- 2020Venting in the comparative study of flexural ultrasonic transducers to improve resilience at elevated environmental pressure levelscitations
- 2020The high frequency flexural ultrasonic transducer for transmitting and receiving ultrasound in aircitations
- 2020The nonlinear dynamics of flexural ultrasonic transducers
- 2020Ultrasonic transducer
- 2020Measurement using flexural ultrasonic transducers in high pressure environmentscitations
- 2019Dynamic nonlinearity in piezoelectric flexural ultrasonic transducerscitations
- 2019Dynamic nonlinearity in piezoelectric flexural ultrasonic transducerscitations
- 2019The Nonlinear Dynamics of Flexural Ultrasonic Transducers
- 2019Wideband electromagnetic dynamic acoustic transducer as a standard acoustic source for air-coupled ultrasonic sensorscitations
- 2018Dynamic characteristics of flexural ultrasonic transducerscitations
- 2018HiFFUTs for high temperature ultrasound
- 2018Nonlinearity in the dynamic response of flexural ultrasonic transducerscitations
- 2018High-frequency measurement of ultrasound using flexural ultrasonic transducerscitations
- 2018Nonlinearity in the dynamic response of the flexural ultrasonic transducerscitations
- 2018The dynamic performance of flexural ultrasonic transducerscitations
- 2017HiFFUTs for High Temperature Ultrasound
- 2017Dynamic Characteristics of Flexural Ultrasonic Transducerscitations
- 2017Ultrasonic compaction of granular geological materialscitations
- 2016An ultrasonic orthopaedic surgical device based on a cymbal transducercitations
- 2016Optimisation of a cymbal transducer for its use in a high-power ultrasonic cutting device for bone surgerycitations
- 2016Dynamics characterisation of cymbal transducers for power ultrasonics applicationscitations
- 2014A cymbal transducer for power ultrasonics applicationscitations
- 2014Nitinol cymbal transducers for tuneable ultrasonic devices
Places of action
Organizations | Location | People |
---|
article
The dynamic performance of flexural ultrasonic transducers
Abstract
Flexural ultrasonic transducers are principally used as proximity sensors and for industrial metrology. Their operation relies on a piezoelectric ceramic to generate a flexing of a metallic membrane, which delivers the ultrasound signal. The performance of flexural ultrasonic transducers has been largely limited to excitation through a short voltage burst signal at a designated mechanical resonance frequency. However, a steady-state amplitude response is not generated instantaneously in a flexural ultrasonic transducer from a drive excitation signal, and differences in the drive characteristics between transmitting and receiving transducers can affect the measured response. This research investigates the dynamic performance of flexural ultrasonic transducers using acoustic microphone measurements and laser Doppler vibrometry, supported by a detailed mechanical analog model, in a process which has not before been applied to the flexural ultrasonic transducer. These techniques are employed to gain insights into the physics of their vibration behaviour, vital for the optimisation of industrial ultrasound systems.