People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Borowski, Tomasz
Warsaw University of Technology
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (22/22 displayed)
- 2023Abrasive Wear Resistance of Ultrafine Ausferritic Ductile Iron Intended for the Manufacture of Gears for Mining Machinerycitations
- 2022Mechanical Behavior of Nitrocarburised Austenitic Steel Coated with N-DLC by Means of DC and Pulsed Glow Dischargecitations
- 2021Enhancing the Corrosion Resistance of Austenitic Steel Using Active Screen Plasma Nitriding and Nitrocarburisingcitations
- 2021Shaping the structure and properties of titanium and Ti6Al7Nb titanium alloy in low-temperature plasma nitriding processescitations
- 2021Formation of Nitrogen Doped Titanium Dioxide Surface Layer on NiTi Shape Memory Alloycitations
- 2021The Microstructure and Properties of Carbon Thin Films on Nanobainitic Steelcitations
- 2020Influence of nitrided and nitrocarburised layers on the functional properties of nitrogen-doped soft carbon-based coatings deposited on 316L steel under DC glow-discharge conditionscitations
- 2020Effect of Nitrided and Nitrocarburised Austenite on Pitting and Crevice Corrosion Resistance of 316 LVM Steel Implantscitations
- 2020CORROSION RESISTANCE OF NITROGEN-DOPED DLC COATINGS PRODUCED IN GLOW DISCHARGE CONDITIONS ON NITRIDED AUSTENITIC STEELcitations
- 2019Microstructural and corrosion resistance characterisation of NiTi shape memory alloy modified at low-temperature plasma with carbon coatings produced via RFCVD and IBAD methodscitations
- 2018Influence of Sterilization and Exposure to the Ringer’s Solution on Mechanical and Physicochemical Properties of Nitrocarburized 316 LVM Steelcitations
- 2017Influence of amorphous carbon layers on tribological properties of polyetheretherketone composite in contactwith nitrided layer produced on Ti6Al4V titanium alloycitations
- 2017NiTi shape-memory alloy oxidized in low-temperature plasma with carbon coating: Characteristic and a potential for cardiovascular applicationscitations
- 2016Cathodic Cage Plasma Nitriding of Ti6Al4V Alloycitations
- 2016Influence of Nitrided Layer on the Properties of Carbon Coatings Produced on X105CrMo17 Steel Under DC Glow-Discharge Conditionscitations
- 2016Wpływ topografii powierzchni na odporność korozyjną stopu z pamięcią kształtu NiTi po procesie azotowania jarzeniowego w niskotemperaturowej plazmie / Influence of surface topography on the corrosion resistance of NiTi shape memory alloy nitrided at low-temperature plasma process
- 2015Surface Modification of Austenitic Steel by Various Glow-Discharge Nitriding Methodscitations
- 2011Oxynitrided Surface Layer Produced On Ti6Al4V Titanium Alloy Under Low Temperature Glow Discharge Conditions For Medical Applications
- 2011The effect of the diffusive, composite chromium nitride layers produced by a hybrid surface treatment on the corrosion behavior of AZ91D magnesium alloycitations
- 2010Modifying the structure of glow discharge nitrided layers produced on high-nickel chromium-less steel with the participation of an athermal martensitic transformationcitations
- 2009Modifying the properties of the Inconel 625 nickel alloy by glow discharge assisted nitridingcitations
- 2009Effect of the heating temperature on the corrosion resistance of alkali-treated titaniumcitations
Places of action
Organizations | Location | People |
---|
article
Effect of Nitrided and Nitrocarburised Austenite on Pitting and Crevice Corrosion Resistance of 316 LVM Steel Implants
Abstract
Harmful lesions occur in the body around multielement stabilisers made of AISI 316 LVM (Low Vacuum Melted) steel, caused by products of pitting, fretting or crevice corrosion. Preventing the effect is possible by modifying the surface of the steel implants. Therefore, the goal of the paper is the comparison of the mechanical and physiochemical properties of plates for treating deformations of the anterior chest wall made of AISI 316 LVM steel, subjected to diffusion and sterilisation processes and exposed to Ringer’s solution. The surface of the implants was subjected to electrochemical polishing, chemical passivation and, in order to modify their properties, nitrocarburised and nitrided diffusion layers were created on selected stabilisers under glow discharge conditions with the use of an active screen at a temperature of 420 °C, over 60 min. The conducted studies involved the examination of the microstructure of the formed layers, surface roughness testing, analysis of contact angles and surface free energy, examination of resistance to pitting and crevice corrosion and examination of nanohardness. On the basis of the results of the conducted studies, it was established that the most advantageous set of properties after sterilisation and exposure to Ringer’s solution was displayed by implants with a formed diffusion nitrocarburised layer.