People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Virta, Johannes
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (1/1 displayed)
Places of action
Organizations | Location | People |
---|
article
Validation of the X-ray microtomography in the assessment of duodenal morphometry and surface area in celiac disease
Abstract
<jats:sec><jats:title>Background</jats:title><jats:p>Duodenal histology remains the diagnostic reference standard in celiac disease. However, traditional methods have suboptimal sensitivity and reproducibility for early mucosal changes and research purposes. We validated a recently introduced micro-CT imaging method for an accurate digital evaluation of duodenal histomorphometry and mucosal surface areas.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Endoscopic biopsies from 58 individuals were utilized for the micro-CT imaging, selecting histological changes ranging from normal to severely damaged mucosa. The imaging protocol was optimized for practicability and resolution. The Bland–Altman method was applied to test intra- and interobserver variations in the blinded measurements.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>The 3D micro-CT reconstructions enabled easy and precise digital cutting with optimal orientation and computer-assisted measurement of the surface area. Intraobserver analysis of morphological measurements showed a mean difference of 0.011 with limits of agreement (LA) from -0.397 to 0.375 and a standard deviation (SD) of 0.197. The corresponding figures for interobserver analysis were 0.080, from -0.719 to 0.537 and 0.320, respectively. The intraclass correlation coefficients (ICC) for the intraobserver and interobserver variations were 0.981 and 0.954, respectively. Intraobserver surface area analysis yielded a mean difference of 0.010, LA from -0.764 to 0.785 and an SD of 0.395, and an interobserver analysis mean difference of 0.028, LA from -0.642 to 0.698 and SD of 0.342. The respective ICCs for the intra- and interobserver variations were 0.963 and 0.972.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>Micro-CT showed excellent accuracy and reproducibility in the evaluation of mucosal morphometry and surface areas. The improved sensitivity for histological changes is a powerful tool for the diagnosis of celiac disease and for clinical and pharmacological studies.</jats:p></jats:sec>