People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Brahma, Arun
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2015Biomechanical Changes of Collagen Cross-Linking on Human Keratoconic Corneas Using Scanning Acoustic Microscopy.citations
- 2014Biomechanical changes after repeated collagen cross-linking on human corneas assessed in vitro using scanning acoustic microscopycitations
- 2013Biomechanical properties of human corneas following low- and high-intensity collagen cross-linking determined with scanning acoustic microscopycitations
- 2013Scanning acoustic microscopy for mapping the microelastic properties of human corneal tissuecitations
Places of action
Organizations | Location | People |
---|
article
Biomechanical Changes of Collagen Cross-Linking on Human Keratoconic Corneas Using Scanning Acoustic Microscopy.
Abstract
PURPOSE: To assess the biomechanical changes of collagen cross-linking on keratoconic corneas in vitro. METHODS: Six keratoconic corneal buttons were included in this study. Each cornea was divided into two halves, where one half was cross-linked and the other half was treated with riboflavin only and served as control. The biomechanical changes of the corneal tissue were measured across the stroma using scanning acoustic microscopy (SAM). RESULTS: In the cross-linked corneas, there was a steady decrease in the magnitude of speed of sound from the anterior region through to the posterior regions of the stroma. The speed of sound was found to decrease slightly across the corneal thickness in the control corneas. The increase in speed of sound between the cross-linked and control corneas in the anterior region was by a factor of 1.039×. CONCLUSION: A higher speed of sound was detected in cross-linked keratoconic corneal tissue when compared with their controls, using SAM. This in vitro model can be used to compare to the cross-linking results obtained in vivo, as well as comparing the results obtained with different protocols.