People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Aalseth, Craig E.
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (6/6 displayed)
- 2009Initial Component Testing for a Germanium Array Cryostat
- 2008Use of Electrodeposition for Sample Preparation and Rejection Rate Prediction for Assay of Electroformed Ultra High Purity Copper for 232Th and 238U Prior to Inductively Coupled Plasma Mass Spectrometry (ICP/MS)citations
- 2007The Chemistry of Ultra-Radiopure Materials
- 2007Cleaning and passivation of copper surfaces to remove surface radioactivity and prevent oxide formationcitations
- 2007Construction and Testing of a Low-power Cryostat for MARS
- 2005Ultra-Low-Background Copper Production and Clean Fabrication
Places of action
Organizations | Location | People |
---|
report
Construction and Testing of a Low-power Cryostat for MARS
Abstract
A low-power cryostat was designed and built for the Multi-sensor Airborne Radiation Survey (MARS) project for the purpose of housing a close-packed high-purity germanium (HPGe) detector array of 14 HPGe detectors. The power consumption of the cold mass in the cryostat was measured to be 4.07(11) watts, sufficient for 5.5 days of continuous operation using only 8 liters of liquid nitrogen. Temperatures throughout the cryostat were measured by platinum resistance temperature detectors. These measurements were used to determine the emissivity of the copper used in the floating radiation shield and outer cryostat wall, which was constructed using chemically cleaned and passivated copper metal. Using a PNNL-developed passivation process, an emissivity of 2.5(3)% was achieved for copper.