People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Dal Piva, Amanda
Vrije Universiteit Amsterdam
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (41/41 displayed)
- 2024Effect of Glazing Protocol on the Surface Roughness and Optical Properties of Lithia-Based Glass-Ceramics
- 2024Impact of try-in paste removal on the fatigue behavior of bonded lithium disilicate ceramicscitations
- 2024Repair of monolithic zirconia restorations with different direct resin compositescitations
- 2024Effect of brushing simulation on the wear behavior of repaired CAD-CAM restorationscitations
- 2024Cyclic fatigue of a repaired 4 YSZ ceramiccitations
- 2024Effect of ZrO2 paste, surface treatments, and storage on Weibull characteristics and resin bond strength to zirconiacitations
- 2024Effect of printing layer orientation and polishing on the fatigue strength of 3D-printed dental zirconiacitations
- 2023Does glaze firing affect the strength of advanced lithium disilicate after simulated defects?citations
- 2023Effect of glazing technique and firing on surface roughness and flexural strength of an advanced lithium disilicatecitations
- 2023Post-fatigue fracture load, stress concentration and mechanical properties of feldspathic, leucite- and lithium disilicate-reinforced glass ceramicscitations
- 2023Desgaste das cerâmicas odontológicascitations
- 2023Influence of surface finishing and printing layer orientation on surface roughness and flexural strength of stereolithography-manufactured dental zirconiacitations
- 2023The ability of mouthguards to protect veneered teethcitations
- 2023Fluoride and Calcium Release from Alkasite and Glass Ionomer Restorative Dental Materialscitations
- 2022Mechanical Behavior of Alkasite Posterior Restorations in Comparison to Polymeric Materialscitations
- 2022Comparison of Polishing Systems on the Surface Roughness of Resin Based Composites Containing Different Monomerscitations
- 2022Sintering mode of a translucent Y-TZPcitations
- 2021Toothbrushing wear resistance of stained cad/cam ceramicscitations
- 2021Polymerization shrinkage, hygroscopic expansion, elastic modulus and degree of conversion of different composites for dental applicationcitations
- 2021Effect of surface treatment and glaze application on shade characterized resin-modified ceramic after toothbrushingcitations
- 2020Durability of staining and glazing on a hybrid ceramics after the three-body wearcitations
- 2020Influence of different restorative material and cement on the stress distribution of ceramic veneer in upper central incisor
- 2020Influence of different restorative material and cement on the stress distribution of ceramic veneer in upper central incisor
- 2020Mechanical behavior of implant assisted removable partial denture for Kennedy class II
- 2020Biaxial flexural strength and Weilbull characteristics of adhesively luted hybrid and reinforced CAD/CAM materials to dentincitations
- 2020In vitro evaluation of multi-walled carbon nanotube reinforced nanofibers composites for dental applicationcitations
- 2020Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial denturescitations
- 2020Survival probability of zirconia-reinforced lithium silicate ceramiccitations
- 2019Reinforced glass-ceramicscitations
- 2019Effect of pH variation on the subcritical crack growth parameters of glassy matrix ceramicscitations
- 2019Mechanical behavior of conceptual posterior dental crowns with functional elasticity gradient
- 2019A study on stress distribution to cement layer and root dentin for post and cores made of CAD/CAM materials with different elasticity modulus in the absence of ferrulecitations
- 2019Stress distribution of complete-arch implant-supported prostheses reinforced with silica-nylon meshcitations
- 2019Different combinations of CAD/CAM materials on the biomechanical behavior of a two-piece prosthetic solution
- 2019Influence of Ceramic Materials on Biomechanical Behavior of Implant Supported Fixed Prosthesis with Hybrid Abutmentcitations
- 2018Do mechanical advantages exist in relining fiber posts with composite prior to its cementation?citations
- 2018CAD-FEA modeling and analysis of different full crown monolithic restorationscitations
- 2018Effect of surface treatments on the bond repair strength of resin composite to different artificial teethcitations
- 2018Influence of different restorative materials on the stress distribution in dental implantscitations
- 2017Comportamento biomecânico de resinas compostas indiretascitations
- 2017Distribuições de tensão e microdeformação em implantes curtos com duas conexões protéticas diferentes - Uma análise in vitro e in silicocitations
Places of action
Organizations | Location | People |
---|
article
Reinforced glass-ceramics
Abstract
<p>The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.</p>