People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Blunt, Liam
University of Huddersfield
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (23/23 displayed)
- 2024Trueness of vat-photopolymerization printing technology of interim fixed partial denture with different building orientationcitations
- 2022Reaction Sintering of Biocompatible Al2O3-hBN Ceramicscitations
- 2020Challenges in Inspecting Internal Features for SLM Additive Manufactured Build Artifactscitations
- 2020The Detection of Unfused Powder in EBM and SLM Additive Manufactured Componentscitations
- 2020Development of an Additive Manufactured Artifact to Characterize Unfused Powder Using Computed Tomographycitations
- 2020Quantification of additive manufacturing induced variations in the global and local performance characteristics of a complex multi-stage control valve trimcitations
- 2019Introduction of a Surface Characterization Parameter Sdrprime for Analysis of Re-entrant Featurescitations
- 2019Hot-melt extrusion process impact on polymer choice of glyburide solid dispersionscitations
- 2019The challenges in edge detection and porosity analysis for dissimilar materials additive manufactured components
- 2018Optimization of surface determination strategies to enhance detection of unfused powder in metal additive manufactured components
- 2018Development of an AM artefact to characterize unfused powder using computer tomography
- 2018Characterisation of powder-filled defects in additive manufactured surfaces using X-ray CT
- 2018An interlaboratory comparison of X-ray computed tomography measurement for texture and dimensional characterisation of additively manufactured partscitations
- 2017Areal surface texture data extraction from X-ray computed tomography reconstructions of metal additively manufactured partscitations
- 2017Results from an interlaboratory comparison of areal surface texture parameter extraction from X-ray computed tomography of additively manufactured parts
- 2017Method for characterizing defects/porosity in additive manufactured components using computer tomography
- 2016Method for Characterization of Material Loss from Modular Head-Stem Taper Surfaces of Hip Replacement Devicescitations
- 2015Implementation of wavelength scanning interferometry for R2R flexible PV barrier films
- 2014Defect Detection in Thin-film Photovoltaics; Towards Improved Efficiency and Longevitycitations
- 2014Development of the basis for in process metrology for roll to roll production of flexible photo voltaics
- 2014An interferometric auto-focusing method for on-line defect assessment on a roll-to-roll process using wavelength scanning interferometry
- 2009Comparison of Type F2 Software Measurement Standards for Surface Texture
- 2006The use of CMM techniques to assess the wear of total knee replacements
Places of action
Organizations | Location | People |
---|
document
Method for Characterization of Material Loss from Modular Head-Stem Taper Surfaces of Hip Replacement Devices
Abstract
Assessment of the head-stem taper junction requires the estimation of material loss from the taper surfaces of both femoral head and stem. This paper describes a method for the measurement and analysis of material loss from the modular taper junction of hip replacements, in particular femoral stem tapers for which the entire taper surface generally has been engaged. In such cases, no direct unengaged datum surface is readily identifiable to assess material loss. The highly anisotropic topology of some stem designs poses additional challenges to the measurement and analysis process. Estimation of material loss of retrieved femoral stems is further complicated by retrieval damage or surface deposits often present on the taper surface. The femoral head tapers typically exhibit areas of pristine surface attributed to the difference in taper length compared with the engaging stem. These areas can be selected as unworn when employed in the analysis process, provided they do not show surface damage or deposits. Measurement of the taper surfaces has been performed using a Talyrond (Ametek, Inc., US) out-of-roundness measurement instrument equipped with a 5-μm diamond tip stylus. Vertical axial traces were employed to digitize the surface of the taper. Measurement data have been analyzed using a multistage process that has been adapted specifically for stem tapers. The underlying stem taper geometry is determined by means of a morphological filter applied to the high-aspect ratio microstructure. This paper presents a study of 40 retrieved large-head metal-on-metal hip replacements that have been analyzed to ascertain the material loss at the modular taper junction. The purpose of this study was to ascertain the viability of characterizing material loss from the stem taper junction and to provide insight into the overall material loss contribution.