Materials Map

Discover the materials research landscape. Find experts, partners, networks.

  • About
  • Privacy Policy
  • Legal Notice
  • Contact

The Materials Map is an open tool for improving networking and interdisciplinary exchange within materials research. It enables cross-database search for cooperation and network partners and discovering of the research landscape.

The dashboard provides detailed information about the selected scientist, e.g. publications. The dashboard can be filtered and shows the relationship to co-authors in different diagrams. In addition, a link is provided to find contact information.

×

Materials Map under construction

The Materials Map is still under development. In its current state, it is only based on one single data source and, thus, incomplete and contains duplicates. We are working on incorporating new open data sources like ORCID to improve the quality and the timeliness of our data. We will update Materials Map as soon as possible and kindly ask for your patience.

To Graph

1.080 Topics available

To Map

977 Locations available

693.932 PEOPLE
693.932 People People

693.932 People

Show results for 693.932 people that are selected by your search filters.

←

Page 1 of 27758

→
←

Page 1 of 0

→
PeopleLocationsStatistics
Naji, M.
  • 2
  • 13
  • 3
  • 2025
Motta, Antonella
  • 8
  • 52
  • 159
  • 2025
Aletan, Dirar
  • 1
  • 1
  • 0
  • 2025
Mohamed, Tarek
  • 1
  • 7
  • 2
  • 2025
Ertürk, Emre
  • 2
  • 3
  • 0
  • 2025
Taccardi, Nicola
  • 9
  • 81
  • 75
  • 2025
Kononenko, Denys
  • 1
  • 8
  • 2
  • 2025
Petrov, R. H.Madrid
  • 46
  • 125
  • 1k
  • 2025
Alshaaer, MazenBrussels
  • 17
  • 31
  • 172
  • 2025
Bih, L.
  • 15
  • 44
  • 145
  • 2025
Casati, R.
  • 31
  • 86
  • 661
  • 2025
Muller, Hermance
  • 1
  • 11
  • 0
  • 2025
Kočí, JanPrague
  • 28
  • 34
  • 209
  • 2025
Šuljagić, Marija
  • 10
  • 33
  • 43
  • 2025
Kalteremidou, Kalliopi-ArtemiBrussels
  • 14
  • 22
  • 158
  • 2025
Azam, Siraj
  • 1
  • 3
  • 2
  • 2025
Ospanova, Alyiya
  • 1
  • 6
  • 0
  • 2025
Blanpain, Bart
  • 568
  • 653
  • 13k
  • 2025
Ali, M. A.
  • 7
  • 75
  • 187
  • 2025
Popa, V.
  • 5
  • 12
  • 45
  • 2025
Rančić, M.
  • 2
  • 13
  • 0
  • 2025
Ollier, Nadège
  • 28
  • 75
  • 239
  • 2025
Azevedo, Nuno Monteiro
  • 4
  • 8
  • 25
  • 2025
Landes, Michael
  • 1
  • 9
  • 2
  • 2025
Rignanese, Gian-Marco
  • 15
  • 98
  • 805
  • 2025

Fessler, Jeffrey A.

  • Google
  • 1
  • 4
  • 4

in Cooperation with on an Cooperation-Score of 37%

Topics

Publications (1/1 displayed)

  • 202390Y SPECT scatter estimation and voxel dosimetry in radioembolization using a unified deep learning framework4citations

Places of action

Chart of shared publication
Jia, Yixuan
1 / 2 shared
Akhavanallaf, Azadeh
1 / 2 shared
Li, Zongyu
1 / 1 shared
Dewaraja, Yuni K.
1 / 1 shared
Chart of publication period
2023

Co-Authors (by relevance)

  • Jia, Yixuan
  • Akhavanallaf, Azadeh
  • Li, Zongyu
  • Dewaraja, Yuni K.
OrganizationsLocationPeople

article

90Y SPECT scatter estimation and voxel dosimetry in radioembolization using a unified deep learning framework

  • Jia, Yixuan
  • Akhavanallaf, Azadeh
  • Li, Zongyu
  • Dewaraja, Yuni K.
  • Fessler, Jeffrey A.
Abstract

<jats:title>Abstract</jats:title><jats:sec><jats:title>Purpose</jats:title><jats:p>90Y SPECT-based dosimetry following radioembolization (RE) in liver malignancies is challenging due to the inherent scatter and the poor spatial resolution of bremsstrahlung SPECT. This study explores a deep-learning-based absorbed dose-rate estimation method for 90Y that mitigates the impact of poor SPECT image quality on dosimetry and the accuracy–efficiency trade-off of Monte Carlo (MC)-based scatter estimation and voxel dosimetry methods.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Our unified framework consists of three stages: convolutional neural network (CNN)-based bremsstrahlung scatter estimation, SPECT reconstruction with scatter correction (SC) and absorbed dose-rate map generation with a residual learning network (DblurDoseNet). The input to the framework is the measured SPECT projections and CT, and the output is the absorbed dose-rate map. For training and testing under realistic conditions, we generated a series of virtual patient phantom activity/density maps from post-therapy images of patients treated with 90Y-RE at our clinic. To train the scatter estimation network, we use the scatter projections for phantoms generated from MC simulation as the ground truth (GT). To train the dosimetry network, we use MC dose-rate maps generated directly from the activity/density maps of phantoms as the GT (Phantom + MC Dose). We compared performance of our framework (SPECT w/CNN SC + DblurDoseNet) and MC dosimetry (SPECT w/CNN SC + MC Dose) using normalized root mean square error (NRMSE) and normalized mean absolute error (NMAE) relative to GT.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>When testing on virtual patient phantoms, our CNN predicted scatter projections had NRMSE of 4.0% ± 0.7% on average. For the SPECT reconstruction with CNN SC, we observed a significant improvement on NRMSE (9.2% ± 1.7%), compared to reconstructions with no SC (149.5% ± 31.2%). In terms of virtual patient dose-rate estimation, SPECT w/CNN SC + DblurDoseNet had a NMAE of 8.6% ± 5.7% and 5.4% ± 4.8% in lesions and healthy livers, respectively; compared to 24.0% ± 6.1% and 17.7% ± 2.1% for SPECT w/CNN SC + MC Dose. In patient dose-rate maps, though no GT was available, we observed sharper lesion boundaries and increased lesion-to-background ratios with our framework. For a typical patient data set, the trained networks took ~ 1 s to generate the scatter estimate and ~ 20 s to generate the dose-rate map (matrix size: 512 × 512 × 194) on a single GPU (NVIDIA V100).</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>Our deep learning framework, trained using true activity/density maps, has the potential to outperform non-learning voxel dosimetry methods such as MC that are dependent on SPECT image quality. Across comprehensive testing and evaluations on multiple targeted lesions and healthy livers in virtual patients, our proposed deep learning framework demonstrated higher (66% on average in terms of NMAE) estimation accuracy than the current “gold-standard” MC method. The enhanced computing speed with our framework without sacrificing accuracy is highly relevant for clinical dosimetry following 90Y-RE.</jats:p></jats:sec>

Topics
  • density
  • impedance spectroscopy
  • simulation
  • gold
  • size-exclusion chromatography
  • dosimetry