People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Pegg, Elise Catherine
University of Bath
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (11/11 displayed)
- 2024Auxetic fixation devices can achieve superior pullout performances compared to standard fixation conceptscitations
- 2023A Feasibility Study for Additively Manufactured Composite Tooling
- 2023Additively manufactured cure tools for composites manufacturecitations
- 2017Effect of absorbed fatty acids on physical properties of ultra-high molecular weight polyethylene
- 2017Use of contrast agents on polymeric materials
- 2016Elasto-plastic Material Models Introduce Error in Finite Element Polyethylene Wear Predictions
- 2016A Python Package to Assign Material Properties of Bone to Finite Element Models from within Abaqus Software
- 2016An open source software tool to assign the material properties of bone for ABAQUS finite element simulationscitations
- 2015Tibial Fracture after Unicompartmental Knee Replacement: The Importance of Surgical Cut Accuracy
- 20133D positioning of ACL attachment sites during flexion
- 2013Fracture of mobile unicompartmental knee bearingscitations
Places of action
Organizations | Location | People |
---|
article
Fracture of mobile unicompartmental knee bearings
Abstract
Cases of fractured mobile unicompartmental knee bearings have recently been reported. The purpose of this study was to understand the mechanics behind these fractures and to examine the influence of different design modifications. A parametric finite element model was used to examine the influence of different geometrical factors on the stresses within the bearing. Crack initiation occurred clinically in the centre of the bearing; this correlated with the position of the maximum von Mises stress. Tensile stresses, thought to propagate the fatigue crack, were maximal at the medial-lateral sides of the bearing, and the tensile vectors were normal to the fracture direction observed clinically. Fully congruent femoral articulation on the bearing, use of a thicker bearing size, and minimising wear of the component reduced the risk of fracture. For example, an unworn 6.5-mm-thick bearing (no clinical fractures reported) had 21.6% lower medial-lateral tensile stress compared to an unworn 3.5 mm bearing (five clinical fractures reported). In turn, an unworn 3.5 mm bearing had 34.3% lower tensile stress compared to a 3.5 mm bearing after 1.9 mm wear (average linear wear reported for clinically fractured bearings). The fracture risk was also reduced when the radio-opaque marker wire was positioned further from the centre of the bearing, and when marker balls were used instead of marker wires (19% reduction in tensile stress in some regions). These results indicate the importance of minimising component wear; the data also support the current component design which uses posterior marker balls instead of marker wires, and the continuing use of a congruous femoral component.