People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Shirsat, Mahendra D.
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2023Single-Walled Carbon Nanotubes-Copper Metal-Organic Framework Composite for the Sensitive Detection of Lead Ions in Aqueous Solutionscitations
- 2023Hg<sup>2+</sup> Ions Sensor: Single Walled Carbon Nanotubes Incorporated Zn-Metal Organic Frameworkcitations
- 2018Sensitive detection of heavy metal ions: An electrochemical approachcitations
- 2015Conducting polyaniline nanowire electrode junctioncitations
Places of action
Organizations | Location | People |
---|
article
Hg<sup>2+</sup> Ions Sensor: Single Walled Carbon Nanotubes Incorporated Zn-Metal Organic Framework
Abstract
<jats:p>In the present work, zinc benzene 1,4 dicarboxylate (ZnBDC) metal organic framework (MOF) and its composite with single-walled carbon nanotubes (SWNTs), we called as SWNTs@ZnBDC, has been synthesized by traditional solvothermal method. The synthesized materials have been evaluated withvarious techniques such as Fourier transform infrared spectroscopy, X-ray diffraction (XRD), thermogravimetric-differential thermal analysis, Brunauer–Emmett–Teller surface area analysis, cyclic voltammetry, and electrochemical impedance spectroscopy. The sensor has been fabricatedby depositing SWNTs@ZnBDC MOF on a glassy carbon electrode (GCE). The SWNTs@ZnBDC/GCE electrode shows excellent sensing behaviour in terms of selectivity towards Hg<jats:sup>2+</jats:sup> ions only at pH = 5 and does not show any sensing response towards Pb<jats:sup>2+</jats:sup>, Cr<jats:sup>2+</jats:sup>, Cd<jats:sup>2+</jats:sup>,Cu<jats:sup>2+</jats:sup>, and Ni<jats:sup>2+</jats:sup> ions at a concentration of 1 <jats:italic>μ</jats:italic>M. For the Hg<jats:sup>2+</jats:sup> ions, the sensor shows a high sensitivity of 0.86 <jats:italic>μ</jats:italic>A/nM with a limit of detection of 6.74 nM and a limit of quantification of 5 nM.</jats:p>