People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Rajam, K. S.
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2013Studies on surface structure, morphology and composition of Co-W coatings electrodeposited with direct and pulse current using gluconate bathcitations
- 2013Characterization and microhardness of Co-W coatings electrodeposited at different pH using gluconate bathcitations
- 2013Characterization and hardness of Co-P coatings obtained from direct current electrodeposition using gluconate bathcitations
- 2012Characterization of amorphous Co-P alloy coatings electrodeposited with pulse current using gluconate bathcitations
Places of action
Organizations | Location | People |
---|
article
Studies on surface structure, morphology and composition of Co-W coatings electrodeposited with direct and pulse current using gluconate bath
Abstract
<p>Co-W alloy coatings were deposited with direct current (DC) and pulse current (PC) electrodeposition methods using gluconate bath at pH5 and characterized by X-ray diffraction, field emission scanning electron microscopy, atomic force microscopy, differential scanning calorimetry (DSC) and X-ray photoelectron spectroscopy (XPS). DSC studies hint at the possibility of formation of metallic glasses. Detailed XPS studies of these alloy coatings have been carried out to compare elemental states and composition of Co and W in DC and PC electrodeposited alloys. DC-plated alloy has significant amount of Co and W metal along with their respective oxidized species. In contrast, mainly oxidized metals are present in the following layers of as-deposited coatings prepared with PC plating. Concentration of Co metal is observed to increase during sputtering, whereas there is no change in W<sup>6+</sup> concentration. Microhardness measurement of all the Co-W coatings shows higher hardness compared to Co metal and 1:1 and 1:4 PC electrodeposited coatings show little higher hardness compared to 1:2 PC electrodeposited coating.</p>