People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Himmelhuber, Roland
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (3/3 displayed)
- 2010Alignment-free fabrication of a hybrid electro-optic polymer/ion-exchange glass coplanar modulatorcitations
- 2010Mach-Zehnder interferometry method for decoupling electro-optic and piezoelectric effects in poled polymer filmscitations
- 2010Mach-Zehnder interferometry method for decoupling electro-optic and piezoelectric tensor components in poled polymer filmscitations
Places of action
Organizations | Location | People |
---|
document
Mach-Zehnder interferometry method for decoupling electro-optic and piezoelectric tensor components in poled polymer films
Abstract
A Mach-Zehnder interferometer (MZI) is used to decouple the electro-optic (EO) and piezoelectric tensor components for a poled polymer film. In the past those using the MZI method failed to take into account the piezoelectric contribution in the polymer which can lead to erroneous EO coefficient data. The typical poled sample of polymer sandwiched between ITO glass and gold that was developed for the popular Teng-Man reflection ellipsometry method is used, providing for easy comparison with that method. The sample serves as a mirror in one arm of the interferometer with the gold side facing the beam for measuring the piezoelectric modulation and the glass side facing the beam to measure the coupled piezoelectric and EO modulation. Optical biasing in the reference arm allows for the baseline and modulated contrast of the system to be measured from which the tensor components are calculated. This method has the advantage over the reflection ellipsometry method of allowing for the independent determination of the Pockel's coefficients r<sub>13</sub> and r<sub>33</sub> and the piezoelectric coefficient d<sub>33</sub>. The r<sub>33</sub> value of a guest host polymer that consists of AJLZ53/amorphous polycarbonate (APC) was found to be 122.7 pm/V and 123.0 pm/V for the MZI and reflection ellipsometry method respectively. The r<sub>33</sub> data fits well to the dispersion of the second order susceptibility tensor χ<sub>333</sub><sup>(2)</sup> based on the two-level model approximation. Measurements were done from 100 Hz to 100 kHz with the results showing that at higher frequencies the mechanical effects in the sample are negligible and modulation is almost entirely due to the EO effect, as expected.