People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Cotroneo, V.
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2017Design and development of the multilayer optics for the new hard x-ray missioncitations
- 2012Technology development of adjustable grazing incidence x-ray optics for sub-arc second imagingcitations
- 2008Design and development of the SIMBOL-X hard x-ray opticscitations
- 2007Development of a prototype nickel optic for the Constellation-X hard x-ray telescopecitations
Places of action
Organizations | Location | People |
---|
document
Development of a prototype nickel optic for the Constellation-X hard x-ray telescope
Abstract
The Constellation-X mission concept has been streamlined to a single Atlas V 551 configuration. This decision was reached by the project team after considering the increases in launch costs announced in 2006 coupled with the constrained budget environment apparent with the release of the NASA 2007 budget. Along with the Spectroscopy X-ray Telescopes, this new configuration continues to carry a Hard X-ray Telescope (HXT) component, with some modifications to the original requirements to adjust to the new configuration. The total effective area requirement in the 7 - 40 keV band has been reduced, but at the same time the angular resolution requirement has been increased from 1 arcmin to 30 arcsec. The Smithsonian Astrophysical Observatory, Marshall Space Flight Center and Brera Observatory, Italy) have been collaborating to develop and HXT which meets the requirements of Constellation-X. The development work we have been engaged in to produce multilayer coated Electroformed-Nickel-Replicate (ENR) shells is well suited for this new configuration. We report here on results of fabrication and testing of a prototyped optic for the HXT. Full beam illumination X-ray tests, taken at MPE-Panter Test Facility, show that these optics meet the new requirement of 30 arcsec for the streamlined Constellation-X configuration. This report also presents preliminary results from studies using titanium nitride as a release agent to simplify and improve the nickel electroforming replication process....