People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Basso, Stefano
Brera Astronomical Observatory
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (13/13 displayed)
- 2014Evaluation of the surface strength of glass plates shaped by hot slumping processcitations
- 2013Accurate integration of segmented x-ray optics using interfacing ribscitations
- 2010The optics system of the New Hard X-ray Mission: design and developmentcitations
- 2009Design And Development The Ixo Mirrors By Innovative Slumping Glass Technologies
- 2009Stiff and Lightweight Optical Mirrors Made by Glass Slumping with Foamed Core
- 2009Design and development of the optics system for the NHXM Hard X-ray and Polarimetric Missioncitations
- 2009Technologies for manufacturing of high angular resolution multilayer coated optics for future new hard x-ray missions: a status reportcitations
- 2008Simbol-X mirror module design scientific optimization.
- 2008Design and development of the SIMBOL-X hard x-ray opticscitations
- 2008Feasibility study for the manufacturing of the multilayer X-ray optics for Simbol-X
- 2008The relation between the weight and the quality image in a X-ray telescope, with a particular regard to Simbol-X
- 2007Development of a prototype nickel optic for the Constellation-X hard x-ray telescopecitations
- 2005Development of grazing-incidence multilayer mirrors by direct Ni electroforming replication: a status reportcitations
Places of action
Organizations | Location | People |
---|
document
Development of a prototype nickel optic for the Constellation-X hard x-ray telescope
Abstract
The Constellation-X mission concept has been streamlined to a single Atlas V 551 configuration. This decision was reached by the project team after considering the increases in launch costs announced in 2006 coupled with the constrained budget environment apparent with the release of the NASA 2007 budget. Along with the Spectroscopy X-ray Telescopes, this new configuration continues to carry a Hard X-ray Telescope (HXT) component, with some modifications to the original requirements to adjust to the new configuration. The total effective area requirement in the 7 - 40 keV band has been reduced, but at the same time the angular resolution requirement has been increased from 1 arcmin to 30 arcsec. The Smithsonian Astrophysical Observatory, Marshall Space Flight Center and Brera Observatory, Italy) have been collaborating to develop and HXT which meets the requirements of Constellation-X. The development work we have been engaged in to produce multilayer coated Electroformed-Nickel-Replicate (ENR) shells is well suited for this new configuration. We report here on results of fabrication and testing of a prototyped optic for the HXT. Full beam illumination X-ray tests, taken at MPE-Panter Test Facility, show that these optics meet the new requirement of 30 arcsec for the streamlined Constellation-X configuration. This report also presents preliminary results from studies using titanium nitride as a release agent to simplify and improve the nickel electroforming replication process....