People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Shepherd, Duncan Et
University of Birmingham
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (24/24 displayed)
- 2024Frequency and time dependent viscoelastic characterization of pediatric porcine brain tissue in compressioncitations
- 2022Bio-Tribo-Acoustic Emissions: Condition Monitoring of a Simulated Joint Articulationcitations
- 2022Long-term in vitro corrosion behavior of Zn-3Ag and Zn-3Ag-0.5Mg alloys considered for biodegradable implant applicationscitations
- 2022Surface Free Energy Dominates the Biological Interactions of Postprocessed Additively Manufactured Ti-6Al-4Vcitations
- 2021Surface finish of additively manufactured metalscitations
- 2021Investigation of the compressive viscoelastic properties of brain tissue under time and frequency dependent loading conditionscitations
- 2020Dynamic mechanical characterization and viscoelastic modeling of bovine brain tissuecitations
- 2020A method for the assessment of the coefficient of friction of articular cartilage and a replacement biomaterialcitations
- 2019Frequency dependent viscoelastic properties of porcine brain tissuecitations
- 2018The role of subchondral bone, and its histomorphology, on the dynamic viscoelasticity of cartilage, bone and osteochondral corescitations
- 2018Tailoring selective laser melting process for titanium drug-delivering implants with releasing micro-channelscitations
- 2017Crack growth in medical-grade silicone and polyurethane ether elastomerscitations
- 2016Design of a Dynamic External Finger Fixatorcitations
- 2015Frequency dependent viscoelastic properties of porcine bladdercitations
- 2015The evolution of polymer wear debris from total disc arthroplastycitations
- 2015Variation in viscoelastic properties of bovine articular cartilage below, up to and above healthy gait-relevant loading frequenciescitations
- 2014Viscoelastic properties of bovine knee joint articular cartilage : dependency on thickness and loading frequencycitations
- 2013Abrasive Water Jet Cutting (AWJC) of Co-Cr-Mo alloy investment castings in the medical device industry
- 2011Viscoelastic properties of the intervertebral disc and the effect of nucleus pulposus removalcitations
- 2010Effect of accelerated aging on the viscoelastic properties of Elast-Eon (TM): A polyurethane with soft poly(dimethylsiloxane) and poly(hexamethylene oxide) segmentscitations
- 2009Viscoelastic properties of bovine articular cartilage attached to subchondral bone at high frequenciescitations
- 2009Frequency dependence of viscoelastic properties of medical grade siliconescitations
- 2005A new design concept for wrist arthroplastycitations
- 2004A comparison of the torsional performance of stainless steel and titanium alloy tibial intramedullary nails: a clinically relevant approach
Places of action
Organizations | Location | People |
---|
article
Design of a Dynamic External Finger Fixator
Abstract
This paper describes an improved design of an external fixator. The new fixator comprises 13 parts which are assembled together. The proposed device materials consist of polyether ether-ketone (PEEK) and stainless steel 316L. The design was subjected to finite-element analysis, and a working model was manufactured and subjected to cyclic mechanical testing. The finite-element analysis showed that the maximum stress was 242.9 MPa and this was less than the yield strength and the fatigue endurance limits for the selected materials. Mechanical testing showed that testing reached run-out of 170,000 cycles with no cracks or damage visible in the device parts.