People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Drinkwater, Bw
University of Bristol
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (25/25 displayed)
- 2021Exploring high-frequency eddy-current testing for sub-aperture defect characterisation using parametric-manifold mappingcitations
- 2018Characterisation of carbon fibre-reinforced polymer composites through radon-transform analysis of complex eddy-current datacitations
- 2017Three-dimensional ultrasonic trapping of micro-particles in water with a simple and compact two-element transducercitations
- 2016Ultrasonic Array Imaging Through an Anisotropic Austenitic Steel Weld Using an Efficient Ray-tracing Algorithmcitations
- 2014Accurate modelling of anisotropic effects in austenitic stainless steel welds
- 2013Detection of Fibre Waviness Using Ultrasonic Array Scattering Datacitations
- 2013Imaging composite material using ultrasonic arrayscitations
- 2013Effective dynamic moduli and density of fiber-reinforced composites
- 2012Monte Carlo inversion of ultrasonic array data to map anisotropic weld propertiescitations
- 2012Autofocus imaging
- 2012Imaging composite material using ultrasonic arrayscitations
- 2012Effective dynamic constitutive parameters of acoustic metamaterials with random microstructurecitations
- 2010Ultrasonic condition monitoring using thin-film piezoelectric sensorscitations
- 2010Inspection of single crystal aerospace components with ultrasonic arrayscitations
- 2009Measurement of the ultrasonic nonlinearity of kissing bonds in adhesive jointscitations
- 2008Acoustic emission from pitting corrosion in stressed stainless steel platecitations
- 2006Oil film measurement in polytetrafluoroethylene-faced thrust pad bearings for hydrogenerator applicationscitations
- 2006Guided Wave Acoustic Emission from Fatigue Crack Growth in Aluminium Plate
- 2006Monitoring of lubricant film failure in a ball bearing using ultrasoundcitations
- 2006Intra-laminar cracking in CFRP laminatescitations
- 2006Global crack detection for aircraft monitoring using bispectral analysis
- 2006Intra-laminar cracking in CFRP laminates: observations and modelling ; Intra-laminar cracking in CFRP laminates:Observations and modellingcitations
- 2004The on-line measurement of lubricant film thickness for condition monitoringcitations
- 2003An ultrasonic wheel-array sensor and its application to aerospace structurescitations
- 2003The measurement of lubricant-film thickness using ultrasoundcitations
Places of action
Organizations | Location | People |
---|
article
Monitoring of lubricant film failure in a ball bearing using ultrasound
Abstract
A lubricant-film monitoring system for a conventional deep groove ball bearing (type 6016, shaft diameter 80 mm, ball diameter 12.7 mm) is described. A high-frequency (50 MHz) ultrasonic transducer is mounted on the static outer raceway of the bearing. The transducer is focused on the ball-raceway interface and used to measure the reflection coefficient of the lubricant in the "contact" ellipse between bearing components. The reflection coefficient characterizes the lubricant film and can be used to calculate its thickness. An accurate triggering system enables multiple reflection measurements to be made as each lubricated contact moves past the measurement location. Experiments are described in which bearings were deliberately caused to fail by the addition of acetone, water, and sand to the lubricant. The ultrasonic reflection coefficient was monitored as a function of time as the failure occurred. Also monitored were the more standard parameters, temperature and vibration. The results indicate that the ultrasonic measurements are able to detect the failures before seizure. It is also observed that, when used in parallel, these monitoring techniques offer the potential to diagnose the failure mechanism and hence improve predictions of remaining life. ; A lubricant-film monitoring system for a conventional deep groove ball bearing (type 6016, shaft diameter 80 mm, ball diameter 12.7 mm) is described. A high-frequency (50 MHz) ultrasonic transducer is mounted on the static outer raceway of the bearing. The transducer is focused on the ball-raceway interface and used to measure the reflection coefficient of the lubricant in the "contact" ellipse between bearing components. The reflection coefficient characterizes the lubricant film and can be used to calculate its thickness. An accurate triggering system enables multiple reflection measurements to be made as each lubricated contact moves past the measurement location. Experiments are described in which bearings were deliberately caused to fail by the addition of ...