People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Çakmak, Gülce
University of Bern
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (10/10 displayed)
- 2023Surface roughness, optical properties, and microhardness of additively and subtractively manufactured CAD‐CAM materials after brushing and coffee thermal cyclingcitations
- 2023Influence of polishing technique and coffee thermal cycling on the surface roughness and color stability of additively and subtractively manufactured resins used for definitive restorationscitations
- 2023Evaluation of Dimensional Stability and Occlusal Wear of Additively and Subtractively Manufactured Resin-Based Crowns after Thermomechanical Agingcitations
- 2023Flexural strength, surface roughness, and biofilm formation of ceramic‐reinforced PEEK: An in vitro comparative studycitations
- 2023Flexural Strength and Vickers Microhardness of Graphene-Doped SnO2 Thin-Film-Coated Polymethylmethacrylate after Thermocyclingcitations
- 2020The effect of scanner type and scan body position on the accuracy of complete‐arch digital implant scanscitations
- 2019Effect of Surface Finishing Methods and Aging on Surface Roughness and Optical Properties of Zirconia-Reinforced Lithium Silicate Glass-Ceramiccitations
- 2019Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymerscitations
- 2018Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures.
- 2017Repair bond strengths of non-aged and aged resin nanoceramics.citations
Places of action
Organizations | Location | People |
---|
article
Influence of polishing technique and coffee thermal cycling on the surface roughness and color stability of additively and subtractively manufactured resins used for definitive restorations
Abstract
<jats:title>Abstract</jats:title><jats:sec><jats:title>Purpose</jats:title><jats:p>To evaluate how different polishing techniques and coffee thermal cycling affect the surface roughness and stainability of additively and subtractively manufactured resins used for definitive prostheses.</jats:p></jats:sec><jats:sec><jats:title>Materials and Methods</jats:title><jats:p>Two additively manufactured composite resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 90 rectangular‐shaped specimens (14 × 12 × 1 mm) (<jats:italic>n</jats:italic> = 30). After baseline surface roughness (<jats:italic>R</jats:italic><jats:sub>a</jats:sub>) measurements, specimens were divided into three groups based on the polishing technique; conventional polishing with a 2‐stage polishing kit (CP) and surface sealant application (Optiglaze, OG or Vita Akzent LC, VA) (<jats:italic>n</jats:italic> = 10). After polishing, specimens were subjected to 10,000 cycles of coffee thermal cycling. <jats:italic>R</jats:italic><jats:sub>a</jats:sub> and color coordinate measurements were performed after polishing and after coffee thermal cycling. Color difference (ΔE<jats:sub>00</jats:sub>) was calculated. Scanning electron microscope images were taken at each time interval. Kruskal–Wallis or 1‐way analysis of variance (ANOVA) were used to evaluate <jats:italic>R</jats:italic><jats:sub>a</jats:sub> of materials within each polishing‐time interval pair and different polishing techniques within each material‐time interval pair, while Friedman or repeated measures ANOVA were used to evaluate <jats:italic>R</jats:italic><jats:sub>a</jats:sub> at different time intervals within each material‐polishing pair. ΔE<jats:sub>00</jats:sub> was assessed with 2‐way ANOVA (<jats:italic>α</jats:italic> = 0.05).</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Other than VA‐after polishing (<jats:italic>p</jats:italic> = 0.055), tested materials had significantly different <jats:italic>R</jats:italic><jats:sub>a</jats:sub> within each polishing‐time interval pair (<jats:italic>p</jats:italic> ≤ 0.038). When <jats:italic>R</jats:italic><jats:sub>a</jats:sub> differences among different polishing techniques within each material‐time interval pair were considered, CS had differences after coffee thermal cycling, CT had differences before polishing and after coffee thermal cycling, and VS had differences within each time interval (<jats:italic>p</jats:italic> ≤ 0.038). When <jats:italic>R</jats:italic><jats:sub>a</jats:sub> differences among different time intervals within each material‐polishing pair were considered, significant differences were observed among all pairs (<jats:italic>p</jats:italic> ≤ 0.016), except for CS‐VA (<jats:italic>p</jats:italic> = 0.695) and VS‐VA (<jats:italic>p</jats:italic> = 0.300). ΔE<jats:sub>00</jats:sub> values were affected by material and polishing technique interaction (<jats:italic>p</jats:italic> = 0.007).</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p><jats:italic>R</jats:italic><jats:sub>a</jats:sub> of CS was similar to or lower than the <jats:italic>R</jats:italic><jats:sub>a</jats:sub> of other materials, regardless of the time interval or polishing technique. CP mostly led to lower <jats:italic>R</jats:italic><jats:sub>a</jats:sub> than other polishing techniques, whereas VA resulted in a high <jats:italic>R</jats:italic><jats:sub>a</jats:sub> regardless of the material‐time interval pair. Polishing reduced the <jats:italic>R</jats:italic><jats:sub>a</jats:sub>, while coffee thermal cycling was found to have a small effect. Among tested material‐polishing pairs, only CS‐VA had moderately unacceptable color change when previously reported threshold values were considered.</jats:p></jats:sec>