Materials Map

Discover the materials research landscape. Find experts, partners, networks.

  • About
  • Privacy Policy
  • Legal Notice
  • Contact

The Materials Map is an open tool for improving networking and interdisciplinary exchange within materials research. It enables cross-database search for cooperation and network partners and discovering of the research landscape.

The dashboard provides detailed information about the selected scientist, e.g. publications. The dashboard can be filtered and shows the relationship to co-authors in different diagrams. In addition, a link is provided to find contact information.

×

Materials Map under construction

The Materials Map is still under development. In its current state, it is only based on one single data source and, thus, incomplete and contains duplicates. We are working on incorporating new open data sources like ORCID to improve the quality and the timeliness of our data. We will update Materials Map as soon as possible and kindly ask for your patience.

To Graph

1.080 Topics available

To Map

977 Locations available

693.932 PEOPLE
693.932 People People

693.932 People

Show results for 693.932 people that are selected by your search filters.

←

Page 1 of 27758

→
←

Page 1 of 0

→
PeopleLocationsStatistics
Naji, M.
  • 2
  • 13
  • 3
  • 2025
Motta, Antonella
  • 8
  • 52
  • 159
  • 2025
Aletan, Dirar
  • 1
  • 1
  • 0
  • 2025
Mohamed, Tarek
  • 1
  • 7
  • 2
  • 2025
Ertürk, Emre
  • 2
  • 3
  • 0
  • 2025
Taccardi, Nicola
  • 9
  • 81
  • 75
  • 2025
Kononenko, Denys
  • 1
  • 8
  • 2
  • 2025
Petrov, R. H.Madrid
  • 46
  • 125
  • 1k
  • 2025
Alshaaer, MazenBrussels
  • 17
  • 31
  • 172
  • 2025
Bih, L.
  • 15
  • 44
  • 145
  • 2025
Casati, R.
  • 31
  • 86
  • 661
  • 2025
Muller, Hermance
  • 1
  • 11
  • 0
  • 2025
Kočí, JanPrague
  • 28
  • 34
  • 209
  • 2025
Šuljagić, Marija
  • 10
  • 33
  • 43
  • 2025
Kalteremidou, Kalliopi-ArtemiBrussels
  • 14
  • 22
  • 158
  • 2025
Azam, Siraj
  • 1
  • 3
  • 2
  • 2025
Ospanova, Alyiya
  • 1
  • 6
  • 0
  • 2025
Blanpain, Bart
  • 568
  • 653
  • 13k
  • 2025
Ali, M. A.
  • 7
  • 75
  • 187
  • 2025
Popa, V.
  • 5
  • 12
  • 45
  • 2025
Rančić, M.
  • 2
  • 13
  • 0
  • 2025
Ollier, Nadège
  • 28
  • 75
  • 239
  • 2025
Azevedo, Nuno Monteiro
  • 4
  • 8
  • 25
  • 2025
Landes, Michael
  • 1
  • 9
  • 2
  • 2025
Rignanese, Gian-Marco
  • 15
  • 98
  • 805
  • 2025

Stuart, Matthias Bo

  • Google
  • 7
  • 23
  • 87

Technical University of Denmark

in Cooperation with on an Cooperation-Score of 37%

Topics

Publications (7/7 displayed)

  • 2023Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers4citations
  • 2022A Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging5citations
  • 2019Imaging Performance for Two Row–Column Arrays38citations
  • 2018Probe development of CMUT and PZT row-column-addressed 2-D arrays29citations
  • 2018Design of a novel zig-zag 192+192 Row Column Addressed Array Transducer: A simulation study.4citations
  • 20163-D Vector Flow Using a Row-Column Addressed CMUT Array7citations
  • 2011Performance Evaluation of a Synthetic Aperture Real-Time Ultrasound Systemcitations

Places of action

Chart of shared publication
Tomov, Borislav Gueorguiev
3 / 5 shared
Øygard, Sigrid Husebø
1 / 1 shared
Thomsen, Erik Vilain
6 / 28 shared
Jensen, Jørgen Arendt
7 / 26 shared
Ommen, Martin Lind
2 / 5 shared
Larsen, Niels Bent
1 / 22 shared
Diederichsen, Søren Elmin
2 / 4 shared
Grass, Rune Sixten
1 / 4 shared
Moesner, Lars N.
1 / 1 shared
Havreland, Andreas S.
1 / 1 shared
Bhatti, Mudabbir T.
1 / 1 shared
Beers, Christopher
3 / 6 shared
Engholm, Mathias
5 / 14 shared
Pedersen, Stine Løvholt Grue
1 / 3 shared
Nikolov, Svetoslav Ivanov
1 / 2 shared
Bouzari, Hamed
2 / 3 shared
Moesner, Lars Nordahl
2 / 4 shared
Christiansen, Thomas Lehrmann
2 / 11 shared
Bagge, Jan Peter
2 / 4 shared
Schou, Mikkel
1 / 3 shared
Havreland, Andreas Spandet
1 / 6 shared
Lei, Anders
1 / 3 shared
Holbek, Simon
1 / 1 shared
Chart of publication period
2023
2022
2019
2018
2016
2011

Co-Authors (by relevance)

  • Tomov, Borislav Gueorguiev
  • Øygard, Sigrid Husebø
  • Thomsen, Erik Vilain
  • Jensen, Jørgen Arendt
  • Ommen, Martin Lind
  • Larsen, Niels Bent
  • Diederichsen, Søren Elmin
  • Grass, Rune Sixten
  • Moesner, Lars N.
  • Havreland, Andreas S.
  • Bhatti, Mudabbir T.
  • Beers, Christopher
  • Engholm, Mathias
  • Pedersen, Stine Løvholt Grue
  • Nikolov, Svetoslav Ivanov
  • Bouzari, Hamed
  • Moesner, Lars Nordahl
  • Christiansen, Thomas Lehrmann
  • Bagge, Jan Peter
  • Schou, Mikkel
  • Havreland, Andreas Spandet
  • Lei, Anders
  • Holbek, Simon
OrganizationsLocationPeople

article

Imaging Performance for Two Row–Column Arrays

  • Nikolov, Svetoslav Ivanov
  • Thomsen, Erik Vilain
  • Jensen, Jørgen Arendt
  • Stuart, Matthias Bo
  • Engholm, Mathias
  • Bouzari, Hamed
Abstract

This study evaluates the volumetric imaging performance of two prototyped 62+62 row–column-addressed (RCA) 2-D array transducer probes using three Synthetic Aperture Imaging (SAI) emission sequences and two different beamsformers. The probes are fabricated using capacitive micromachined ultrasonic transducer (CMUT), and piezoelectric transducer (PZT) technology. Both have integrated apodization to reduce ghost echoes and are designed with similar acoustical features i.e., 3MHz center frequency, l/2-pitch, and 24.8×24.8mm2 active footprint. Raw RF data are obtained using an experimental research ultrasound scanner, SARUS. The SAI sequences are designed for imaging down to 14 cm at a volume rate of 88 Hz. Two beamforming methods: Spatial matched filtering and rowcolumn adapted delay-and-sum are used for beamforming the RF data. The imaging quality is investigated through simulations and phantom measurements. Both probes on average have similar lateral full-width at half-maximum (FWHM) values, but the PZT probe has 20% smaller cystic resolution values and 70% larger contrast-to-noise ratio compared to the CMUT probe. The CMUT probe can penetrate down to 15 cm, and the PZT probe down to 30 cm. The CMUT probe has 17% smaller axial FWHM values. The matched filter focusing shows and improved B-mode image for measurements on a cyst phantom with an improved speckle pattern and better visualization of deeper lying cysts. The results of this study demonstrate the potentials of RCA 2-D arrays against fully addressed 2-D arrays, which are low channel count (e.g. 124 instead of 3,844), low acoustic intensity (MI ≤0.88 and Ispta ≤5.5mW/cm2), and high penetration depth (down to 30 cm), which makes 3-D imaging at high volume rates possible with equipment in the price range of conventional 2-D imaging.

Topics
  • impedance spectroscopy
  • simulation
  • ultrasonic