People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Soleimani, Vahid
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (1/1 displayed)
Places of action
Organizations | Location | People |
---|
article
Depth-based Whole Body Photoplethysmography in Remote Pulmonary Function Testing
Abstract
Objective: We propose a novel depth-based Photoplethysmography (dPPG) approach to reduce motion artifacts in respiratory volume–time data and improve the accuracy of remote pulmonary function testing (PFT) measures.<br/><br/>Method: Following spatial and temporal calibration of two opposing RGB-D sensors, a dynamic 3-D model of the subject performing PFT is reconstructed and used to decouple trunk movements from respiratory motions. Depth-based volume–time data is then retrieved, calibrated and used to compute 11 clinical PFT measures for forced vital capacity (FVC) and slow vital capacity (SVC) spirometry tests.<br/><br/>Results: A dataset of 35 subjects (298 sequences) was collected and used to evaluate the proposed dPPG method by comparing depth-based PFT measures to the measures provided by a spirometer. Other comparative experiments between the dPPG and the single Kinect approach, such as Bland-Altman analysis, similarity measures performance, intra-subject error analysis, and statistical analysis of tidal volume and main effort scaling factors, all show the superior accuracy of the dPPG approach.<br/><br/>Conclusion: We introduce a depth-based whole body photoplethysmography approach which reduces motion artifacts in depth-based volume–time data and highly improves the accuracy of depth-based computed measures.<br/><br/>Significance: The proposed dPPG method remarkably drops the L2error mean and standard deviation of FEF50% , FEF75% , FEF25-75% , IC, and ERV measures by half, compared to the single Kinect approach. These significant improvements establish the potential for unconstrained remote respiratory monitoring and diagnosis.