People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Feeney, Andrew
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (34/34 displayed)
- 2024High Stiffness Resin for Flexural Ultrasonic Transducers
- 2024A 3D-printable metamaterial using a magnetic membrane for tuneable acoustic resonance at low frequencies
- 2024High Frequency Air-Coupled Ultrasound Measurement with the Flexural Ultrasonic Transducer
- 2024Langevin Transducers Incorporating TPMS Lattice Front Masses
- 2024Characterisation of 3D Printable Material for an Acoustic Metamaterial Cell with Tuneable Resonancecitations
- 2023Flexural ultrasonic transducers with nonmetallic membranes
- 2023Microscale Nitinol Hardness Measurements for Engineering Adaptive Ultrasonic Devices
- 2023Fabrication and Dynamic Characterisation of a Nitinol Langevin Transducer
- 2022Enhanced Resolution Phase Transformations in a Nitinol Cymbal Ultrasonic Devicecitations
- 2021Active damping of ultrasonic receiving sensors through engineered pressure wavescitations
- 2021Higher order modal dynamics of the flexural ultrasonic transducercitations
- 2020Venting in the comparative study of flexural ultrasonic transducers to improve resilience at elevated environmental pressure levelscitations
- 2020The high frequency flexural ultrasonic transducer for transmitting and receiving ultrasound in aircitations
- 2020The nonlinear dynamics of flexural ultrasonic transducers
- 2020Ultrasonic transducer
- 2020Measurement using flexural ultrasonic transducers in high pressure environmentscitations
- 2019Dynamic nonlinearity in piezoelectric flexural ultrasonic transducerscitations
- 2019Dynamic nonlinearity in piezoelectric flexural ultrasonic transducerscitations
- 2019The Nonlinear Dynamics of Flexural Ultrasonic Transducers
- 2019Wideband electromagnetic dynamic acoustic transducer as a standard acoustic source for air-coupled ultrasonic sensorscitations
- 2018Dynamic characteristics of flexural ultrasonic transducerscitations
- 2018HiFFUTs for high temperature ultrasound
- 2018Nonlinearity in the dynamic response of flexural ultrasonic transducerscitations
- 2018High-frequency measurement of ultrasound using flexural ultrasonic transducerscitations
- 2018Nonlinearity in the dynamic response of the flexural ultrasonic transducerscitations
- 2018The dynamic performance of flexural ultrasonic transducerscitations
- 2017HiFFUTs for High Temperature Ultrasound
- 2017Dynamic Characteristics of Flexural Ultrasonic Transducerscitations
- 2017Ultrasonic compaction of granular geological materialscitations
- 2016An ultrasonic orthopaedic surgical device based on a cymbal transducercitations
- 2016Optimisation of a cymbal transducer for its use in a high-power ultrasonic cutting device for bone surgerycitations
- 2016Dynamics characterisation of cymbal transducers for power ultrasonics applicationscitations
- 2014A cymbal transducer for power ultrasonics applicationscitations
- 2014Nitinol cymbal transducers for tuneable ultrasonic devices
Places of action
Organizations | Location | People |
---|
article
Venting in the comparative study of flexural ultrasonic transducers to improve resilience at elevated environmental pressure levels
Abstract
The classical form of a flexural ultrasonic transducer is a piezoelectric ceramic disc bonded to a circular metallic membrane. This ceramic induces vibration modes of the membrane for the generation and detection of ultrasound. The transducer has been popular for proximity sensing and metrology, particularly for industrial applications at ambient pressures around 1 bar. The classical flexural ultrasonic transducer is not designed for operation at elevated pressures, such as those associated with natural gas transportation or petrochemical processes. It is reliant on a rear seal which forms an internal air cavity, making the transducer susceptible to deformation through pressure imbalance. The application potential of the classical transducer is therefore severely limited. In this study, a venting strategy which balances the pressure between the internal transducer structure and the external environment is studied through experimental methods including electrical impedance analysis and pitch-catch ultrasound measurement. The vented transducer is compared with a commercial equivalent in air towards 90 bar. Venting is shown to be viable for a new generation of low cost and robust industrial ultrasonic transducers, suitable for operation at high environmental pressure levels.