Topics
Publications (20/20 displayed)
- 2019Transient contact opening forces in a MEMS switch using Au/MWCNT compositecitations
- 2019Arc modeling to predict arc extinction in low-voltage switching devicescitations
- 2018In-situ contact surface characterization in a MEMS ohmic switch under low current switchingcitations
- 2015Characterisation of nanographite for MEMS resonators
- 2013A review of micro-contact physics for microelectromechanical systems (MEMS) metal contact switchescitations
- 2012The effects of porosity, electrode and barrier materials on the conductivity of piezoelectric ceramics in high humidity and dc electric fieldcitations
- 2009The effect of relative humidity, temperature and electrical field on leakage currents in piezo-ceramic actuators under dc biascitations
- 2009Micro-computer tomography-An aid in the investigation of structural changes in lead zirconate titanate ceramics after temperature-humidity bias testingcitations
- 2009Study of temperature change and vibration induced fretting on intrinsically conducting polymer contact systemscitations
- 2006The contact resistance force relationship of an intrinsically conducting polymer interfacecitations
- 2006The influence of thermal cycling and compressive force on the resistance of poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid)-coated surfacescitations
- 2005Intermittency events in bio-compatible electrical contactscitations
- 2005The fretting characteristics of intrinsically conducting polymer contacts
- 2005Displacement measurements at the connector contact interface employing a novel thick film sensorcitations
- 2004The contact resistance force relationship of an intrinsically conducting polymer interfacecitations
- 2004Minimising fretting slip in connector terminals using conducting polymer contacts
- 2002Fretting in connector terminals using conducting polymer contacts
- 2002Fretting corrosion studies of an extrinsic conducting polymer and tin Interfacecitations
- 2002Fretting corrosion and the reliability of multicontact connector terminalscitations
- 2000Degradation of road tested automotive connectorscitations
Places of action
Organizations | Location | People |
---|
document
Displacement measurements at the connector contact interface employing a novel thick film sensor
Abstract
One of the key failure mechanisms for wiring and connector systems used in the automotive industry is fretting and fretting corrosion at the contact interface of connectors. For many years, procedures have been carried out under laboratory controlled conditions to investigate both thermal and vibration fretting effects using environmental chambers and fretting tests. Both optical and visual inspections have also been adopted to observe the movement at the contact interface. However, these methods can be considerably inconvenient and costly. Furthermore, their suitability for field applications is limited. In order to study the fretting degradation at the actual interface for in-situ measurement effectively, a novel position sensor is designed to monitor the relative displacement. Thick film techniques are employed to fabricate miniaturised and cost effective resistive devices. The sensor is assembled into a connector sample by taking the place of the male component. When the interface experiences movement, the relative displacement of the contact point would cause a corresponding linear change of resistance measured across the male and female connection. The sensors are validated by a series of experiments and subsequently used in a field test to establish the relationships between the fretting effects with temperature, humidity and differential pressure. It is found that variation in differential pressure dominates the behaviour of movement at the contact interface of the well-sealed connector sample while temperature and humidity have negligible influences on the measured relative displacement.