People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Poźniak, Krzysztof
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (18/18 displayed)
- 2019Multichannel Data Acquisition System for GEM Detectors citations
- 2018Advanced real-time data quality monitoring model for tokamak plasma diagnosticscitations
- 2017FPGA-based firmware model for extended measurement systems with data quality monitoring citations
- 2016 Modeling of serial data acquisition structure for GEM detector system in Matlabcitations
- 2016New trends in logic synthesis for both digital designing and data processing citations
- 2016The development of algorithms for the deployment of new version of GEM-detector-based acquisition systemcitations
- 2015Architecture of the Upgraded BCM1F backend Electronics for Beam Conditions and Luminosity Measurementcitations
- 2015The CMS Fast Beams Condition Monitor Back-End Electronics based on MicroTCA technology – status and development
- 2015FPGA based charge acquisition algorithm for soft X-ray diagnostics systemcitations
- 2015Development of low noise CCD readout front-end citations
- 2015OMTF firmware overviewcitations
- 2014Development of GEM Gas Detectors for X-Ray Crystal Spectrometry citations
- 2014The Fast Beam Condition Monitor BCM1F Backend Electronics Upgraded MicroTCA Based Architecturecitations
- 2013Fundamental Data Processing for GEM Detector Measurement System Applied for X - ray Diagnostics of Fusion Plasmas
- 2011Optimization of FPGA processing of GEM detector signal citations
- 2011Development of a 1D Triple GEM X-ray detector for a high-resolution x-ray diagnostics at JET
- 2005Optical network and FPGA/DSP based control system for free electon laser
- 2003Cavity Digital Control Testing System by Simulink Step Operation Method for TESLA Linear Accelerator and Free Electron Laser
Places of action
Organizations | Location | People |
---|
article
Development of GEM Gas Detectors for X-Ray Crystal Spectrometry
Abstract
Two Triple Gas Electron Multiplier (Triple-GEM) detectors were developed for high-resolution X-ray spectroscopy measurements for tokamak plasma to serve as plasma evolution monitoring in soft X-ray region (SXR). They provide energy resolved fast dynamic plasma radiation imaging in the SXR with 0.1 kHz frequency. Detectors were designed and constructed for continuous data-flow precise energy and position measurement of plasma radiation emitted by metal impurities, W46+ and Ni26+ ions, at 2.4 keV and 7.8 keV photon energies, respectively. High counting rate capability of the detecting units has been achieved with good position resolution. This article presents results of the laboratory and tokamak experiments together with the system performance under irradiation by photon flux from the plasma core.