People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Kang, Lei
University of Portsmouth
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (28/28 displayed)
- 2024High Stiffness Resin for Flexural Ultrasonic Transducers
- 2024High Frequency Air-Coupled Ultrasound Measurement with the Flexural Ultrasonic Transducer
- 2023Flexural ultrasonic transducers with nonmetallic membranes
- 2023Numerical investigation of unidirectional generation and reception of circumferential shear horizontal guided waves for defect detection in pipecitations
- 2022Numerical investigation of application of unidirectional generation to improve signal interpretation of circumferential guided waves in pipes for defect detectioncitations
- 2022Numerical investigation of application of unidirectional generation to improve signal interpretation of circumferential guided waves in pipes for defect detectioncitations
- 2021Active damping of ultrasonic receiving sensors through engineered pressure wavescitations
- 2021Higher order modal dynamics of the flexural ultrasonic transducercitations
- 2021Unidirectional shear horizontal wave generation by periodic permanent magnets electromagnetic acoustic transducer with dual linear-coil arraycitations
- 2021Oil filled flexural ultrasonic transducers for resilience in environments of elevated pressurecitations
- 2020Venting in the comparative study of flexural ultrasonic transducers to improve resilience at elevated environmental pressure levelscitations
- 2020The high frequency flexural ultrasonic transducer for transmitting and receiving ultrasound in aircitations
- 2020The nonlinear dynamics of flexural ultrasonic transducers
- 2020Ultrasonic transducer
- 2020Measurement using flexural ultrasonic transducers in high pressure environmentscitations
- 2019Dynamic nonlinearity in piezoelectric flexural ultrasonic transducerscitations
- 2019Dynamic nonlinearity in piezoelectric flexural ultrasonic transducerscitations
- 2019The Nonlinear Dynamics of Flexural Ultrasonic Transducers
- 2019Wideband electromagnetic dynamic acoustic transducer as a standard acoustic source for air-coupled ultrasonic sensorscitations
- 2018Dynamic characteristics of flexural ultrasonic transducerscitations
- 2018HiFFUTs for high temperature ultrasound
- 2018Nonlinearity in the dynamic response of flexural ultrasonic transducerscitations
- 2018High-frequency measurement of ultrasound using flexural ultrasonic transducerscitations
- 2018Nonlinearity in the dynamic response of the flexural ultrasonic transducerscitations
- 2018The dynamic performance of flexural ultrasonic transducerscitations
- 2017HiFFUTs for High Temperature Ultrasound
- 2017Dynamic Characteristics of Flexural Ultrasonic Transducerscitations
- 2016High temperature flexural ultrasonic transducer for non-contact measurement applicationscitations
Places of action
Organizations | Location | People |
---|
article
Higher order modal dynamics of the flexural ultrasonic transducer
Abstract
The flexural ultrasonic transducer (FUT) consists of a piezoelectric ceramic bonded to an edge-clamped elastic plate, for both generation and detection of ultrasound waves. It is typically employed for proximity measurement, such as in automotive parking systems, and for flow measurement in gases and liquids. Conventional industrial applications have generally incorporated FUTs with resonance frequencies up to around 50 kHz. However, there have been recent advances in the understanding of the FUT, both in terms of fabrication and operation, enabling the potential for measurement in a wider range of applications, including those of elevated pressure, temperature, and requiring multiple operating frequencies. Ultrasound measurement with FUTs at frequencies greater than 50 kHz is desirable in a range of applications, including gas and water metering in petrochemical plants, district heating, and power industries. The major restricting limitation of designing transducers to operate at these higher frequencies has been a relatively poor understanding of these transducers work, including optimisation of design and performance, and the few reports into how different modes of a FUT can be utilised for practical and reliable measurement. In this study, the higher order modal dynamics of the FUT are investigated through measurement of high frequency ultrasound waves in air, for different fundamental operating modes. A combination of experimental techniques is applied, comprising electrical impedance analysis and laser Doppler vibrometry. The experimental research is supported by analytical solutions to reveal complex higher order modal dynamics of the FUT. This investigation represents further development in widening the industrial application potential of the FUT.