People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Lyyra, Inari
Tampere University
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (7/7 displayed)
- 2024Composition and Properties of Biodegradable Composites of a Bioactive Glass Filler and a Single Polymer or a Blend Matrix
- 2023Interpretable machine learning methods for monitoring polymer degradation in extrusion of polylactic acidcitations
- 2023Hydrolytic degradation of polylactide/polybutylene succinate blends with bioactive glasscitations
- 2021Impact of glass composition on hydrolytic degradation of polylactide/bioactive glass compositescitations
- 2020Dissolution, bioactivity and osteogenic properties of composites based on polymer and silicate or borosilicate bioactive glasscitations
- 2018Bioresorbable Conductive Wire with Minimal Metal Contentcitations
- 2015Optimising polylactide melt spinning using real-time monitoring
Places of action
Organizations | Location | People |
---|
article
Bioresorbable Conductive Wire with Minimal Metal Content
Abstract
The emergence of transient electronics has created the need for bioresorbable conductive wires for signal and energy transfer. We present a fully bioresorbable wire design where the conductivity is provided by only a few micrometers thick electron-beam evaporated magnesium layer on the surface of a polymer fiber. The structure is electrically insulated with an extrusion coated polymer sheath, which simultaneously serves as a water barrier for the dissolvable magnesium conductor. The resistance of the wires was approximately 1 Ω cm–1 and their functional lifetime in buffer solution was more than 1 week. These properties could be modified by using different conductor materials and film thicknesses. Furthermore, the flexibility of the wires enabled the fabrication of planar radio frequency (RF) coils, which were wirelessly measured. Such coils have the potential to be used as wireless sensors. The wire design provides a basis for bioresorbable wires in applications where only a minimal amount of metal is desired, for example, to avoid toxicity.