People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Stack, Margaret
University of Strathclyde
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (6/6 displayed)
- 2024Investigating the Performance of Glass Fibre-Reinforced Polymer (GFRP) in the Marine Environment for Tidal Energy: Velocity, Particle Size, Impact Angle and Exposure Time Effectscitations
- 2020Mapping Raindrop Erosion of GFRP Composite Wind Turbine Blade Materials: Perspectives on Degradation Effects in Offshore and Acid Rain Environmental Conditionscitations
- 2020Mapping Tribo-Corrosion Behaviour of TI-6AL-4V Eli in Laboratory Simulated Hip Joint Environmentscitations
- 2015An experimental approach to analysing rain droplet impingement on wind turbine blade materials
- 2014Bio-tribocorrosion mechanisms in orthopaedic devicescitations
- 2006Erosion-corrosion of Cr3C2-Ni cermets in salt water
Places of action
Organizations | Location | People |
---|
article
Bio-tribocorrosion mechanisms in orthopaedic devices
Abstract
Load bearing implant prostheses such as orthopaedic hip and knee implants may be considered as tribocorrosion systems since the wear processes are a result of combined mechanical and chemical mechanisms. The long-term success of implant prostheses depends on a number of factors, including age, body weight and activity levels. Pre-clinical testing is therefore crucial in determining the long-term performance, safety and reliability of the implant in-vivo. In this study CoCrMo alloy and UHMWPE couple was tested in a physiological solution of foetal calf serum (FCS) in 0.9 wt. % NaCl to assess the underlying wear mechanisms as a result of applied load (0-5N) and applied potential (-600, -400, -200, 0 and +200 mV). The transitioning behaviours due to micro-abrasion and corrosion were studied; corresponding micro-abrasion-corrosion wear maps were constructed to indicate the mass loss transitions in scope of wastage, mechanisms of wear and synergies between abrasion-corrosion for simulated hip contact conditions.