- 2016Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsycitations
- 2016Loose powder detection and surface characterization in selective laser sintering via optical coherence tomographycitations
- 2013Reduced penetration force through ultrasound activation of a standard needlecitations
- 2012New piezocrystal material in the development of a 96-element array transducer for MR-guided focused ultrasound surgerycitations
- 2012Characterization of PMN-29%PT as a function of temperature and pressurecitations
- 2006Superimposed ultrasonic oscillations in compression tests of aluminiumcitations
- 2002A numerical and experimental study of the indentation mechanics of plasticine
- 2002Wedge indentation of an elasto-viscoplastic material
Places of action
Organizations | Location | People |
---|
article
Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy
Abstract
Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2 mm, length > 65 mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30 mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4 μm at the needle tip with an actuating voltage of 20 V pp . Actuated in longitudinal vibration modes (distal mode at 27.6 kHz and transducer mode at 42.2 kHz) with a drive amplitude of 12-14 V pp , a 120 mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications.