People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
González-Calabuig, Andreu
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (6/6 displayed)
- 2018Bioelectronic tongue using MIP sensors for the resolution of volatile phenolic compounds
- 2018Multivariate Determination of Total Sugar Content and Ethanol in Bioethanol Production Using Carbon Electrodes Modified with MWCNT/MeOOH and Chemometric Data Treatment
- 2016Analysis of Amino Acid Mixtures by Voltammetric Electronic Tongues and Artificial Neural Networks
- 2016Simultaneous Voltammetric Determination of Heavy Metals by Use of Crown Ether-modified Electrodes and Chemometricscitations
- 2016Resolution of galactose, glucose, xylose and mannose in sugarcane bagasse employing a voltammetric electronic tongue formed by metals oxy-hydroxide/MWCNT modified electrodescitations
- 2015Crown ether-modified electrodes for the simultaneous stripping voltammetric determination of Cd(II), Pb(II) and Cu(II)citations
Places of action
Organizations | Location | People |
---|
article
Crown ether-modified electrodes for the simultaneous stripping voltammetric determination of Cd(II), Pb(II) and Cu(II)
Abstract
© 2015 Elsevier B.V. All rights reserved. This work describes the immobilization of 4-carboxybenzo-18-crown-6 (CB-18-crown-6) and 4-carboxybenzo-15-crown-5 (CB-15-crown-5) assisted by lysine on aryl diazonium salt monolayers anchored to the surface of graphite-epoxy composite electrodes (GEC), and their use for the simultaneous determination of Cd(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetry (DPASV). These modified electrodes display a good repeatability and reproducibility with detection and quantification limits at levels of μg L-1 (ppb), confirming their suitability for the determination of Cd(II), Pb(II) and Cu(II) ions in environmental samples. The overlapped nature of the multimetal stripping measurements was resolved by employing the two-sensor array CB-15-crown-5-GEC and CB-18-crown-6-GEC, since the metal complex selectivity exhibited by the considered ligands could add some discrimination power. For the processing of the voltammograms, Discrete Wavelet Transform and Causal Index were selected as preprocessing tools for data compression coupled with an artificial neural network for the modeling of the obtained responses, allowing the resolution of mixtures of these metals with good prediction of their concentrations (correlation with expected values for an external test subset better than 0.942).