People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Bayatsarmadi, Bita
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (2/2 displayed)
Places of action
Organizations | Location | People |
---|
article
Highly stable Li+ selective electrode with metal-organic framework as ion-to-electron transducer
Abstract
<p>Detection of Li<sup>+</sup> ions is vital due to their applications as therapeutic drugs in medicine. In addition, finding Li<sup>+</sup> in geothermal brines is gaining interest because of its application in energy storage systems. Monitoring Li<sup>+</sup> levels in an aqueous environment can be achieved using chemical sensors. Solid-contact sensors (SCS) have attracted significant attention because of their portability, high sensitivity and lack of requirement of calibration. However, most solid-contact sensors suffer from low stability, especially in the long term. As a result, ion-to-electron transducers have been utilized to mitigate this problem. Recently Metal-Organic Frameworks (MOFs) have proven to be excellent candidates for use as ion-to-electron transducers in SCSs. In this study, we have used Ni-HAB MOF to produce a highly stable Li<sup>+</sup> selective electrode. Increasing the thickness of the MOF to 3.28 µm enhanced the sensor's capacitance 100-fold leading to the lowest drift in Li<sup>+</sup> SCSs reported in the literature, 1.15×10<sup>−6</sup> mV/h with a low limit of detection (LOD) of 9.94×10<sup>−7</sup>M and a 57.6 mV/dec sensitivity. The sensor exhibited a linear output and a fast response time of less than 1 s. In addition, the sensor developed was used in a real brine to detect the concentration of Li<sup>+</sup> ions, where the obtained results were in good agreement with the actual concentration of Li<sup>+</sup> ions. This paper offers a solution for the persistent issues of solid-contact sensors such as drift, response time, and limit of detection and paves the way for the miniaturization of sensors to be used in real-life applications.</p>