People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Malinowska, Elżbieta
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (14/14 displayed)
- 2020Promising electrodeposited biocompatible coatings for steel obtained from polymerized microemulsionscitations
- 2019Directly-thiolated graphene based electrochemical sensor for Hg(II) ioncitations
- 2017Graphene Nanoplatelets for Screen-Printed Nonenzymatic Voltammetric H2O2 Sensorscitations
- 2015Electrochemical oligonucleotide-based biosensor for the determination of lead ioncitations
- 2013Development of silicon-based electrochemical transducerscitations
- 2013Oligonucleotide-Based Electrochemical Biosensor for Hg2+ Using Methylene Blue as a Redox Indicatorcitations
- 2009Influence of inner transducer properties on EMF response and stability of solid-contact anion-selective membrane electrodes based on metalloporphyrin ionophorescitations
- 2009New polyacrylate-based lead(II) ion-selective electrodescitations
- 2007Further studies on the role of redox-active monolayer as intermediate phase of solid-state sensorscitations
- 2006CMP(O) tripodands: Synthesis, potentiometric studies and extractionscitations
- 2005Studies on ferrocene organothiol monolayer as an intermediate phase of potentiometric sensors with gold inner contactcitations
- 2004Design of ferrocene organothiol monolayer as intermediate phase for miniaturized electrochemical sensors with gold contact
- 2004Towards advanced chemical microsensors—an overviewcitations
- 2004Polymeric membrane electrodes with enhanced fluoride selectivity using Zr(IV)-porphyrins functioning as neutral carrierscitations
Places of action
Organizations | Location | People |
---|
article
Studies on ferrocene organothiol monolayer as an intermediate phase of potentiometric sensors with gold inner contact
Abstract
Newly designed miniaturized potentiometric ion-selective sensors consisting of silicon-based transducers with Au contact, monolayers of redox-active organothiols and ion-selective polymeric membranes are presented. The purpose of incorporation of self-assembled monolayers is to improve sensors’ EMF stability. The influence of the chemical structure of intermediate layer on the electrochemical characteristics of sensors and the resistance to O2 and CO2 interferences of sensors is described.