People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Ramos, António
University of Aveiro
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2023The Tolerancing Obtained with Binder Jetting Additive Manufacturing Process in 17-4PH Steel - Case Study
- 2022Comparative study of titanium alloys machinability used for medical applicationscitations
- 2021Comparison of CAD-CAM and traditional chairside processing of 4-unit interim prostheses with and without cantileverscitations
- 2018Performance assessment of flat slabs strengthened with a bonded reinforced-concrete overlaycitations
Places of action
Organizations | Location | People |
---|
article
Comparison of CAD-CAM and traditional chairside processing of 4-unit interim prostheses with and without cantilevers
Abstract
<p>Statement of problem: How processing by computer-aided design and computer-aided manufacturing (CAD-CAM) or traditional chairside fabrication techniques affects the presence of defects and the mechanical properties of interim dental prostheses is unclear. Purpose: The purpose of this in vitro study was to compare the effects of CAD-CAM versus traditional chairside material processing on the fracture and biomechanical behavior of 4-unit interim prostheses with and without a cantilever. Material and methods: Two types of 4-unit interim prostheses were fabricated with abutments on the first premolar and first mandibular molar, one from a prefabricated CAD-CAM block and one with a traditional chairside polymer-monomer autopolymerizing acrylic resin (n=10). Both groups were assessed by compressive strength testing and additionally with or without a cantilevered second molar by using a universal testing machine with a 5-kN load cell. A finite element model (FEM) was built by scanning both prosthesis designs. Finite element analysis (FEA) replicated the experimental conditions to evaluate the stress distribution through the prostheses. Results: Interim fixed prostheses manufactured by CAD-CAM showed significantly higher mean fracture loading values (3126 N to 3136 N) than for conventionally made interim fixed prostheses (1287 N to 1390 N) (P=.001). The presence of a cantilever decreased the fracture loading mean values for CAD-CAM (1954 N to 2649 N), although the cantilever did not influence the traditional prostheses (1268 N to 1634 N). The highest von Mises stresses were recorded by FEA on the occlusal surface, with the cantilever design, and at the transition region (connector) between the prosthetic teeth. Conclusions: Interim partial prostheses produced by CAD-CAM had a higher strength than those manufactured traditionally. The presence of a cantilever negatively affected the strength of the prostheses, although the structures manufactured by CAD-CAM still revealed high strength and homogenous stress distribution on occlusal loading.</p>