People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Anisimov, Andrei
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (8/8 displayed)
- 2024Shearography With Thermal Loading For Defect Detection Of Small Defects In Cfrp Composites
- 2023Towards safe shearography inspection of thick composites with controlled surface temperature heatingcitations
- 2022Shearography non-destructive testing of thick GFRP laminatescitations
- 2022Shearography non-destructive testing of a composite ship hull section subjected to multiple impacts
- 2021Spatially modulated thermal excitations for shearography non-destructive inspection of thick compositescitations
- 2018EXTREME shearographycitations
- 2017Epoxy-hBN nanocompositescitations
- 2016Thermal strains in heated Fiber Metal Laminates
Places of action
Organizations | Location | People |
---|
article
Towards safe shearography inspection of thick composites with controlled surface temperature heating
Abstract
Thick glass fiber-reinforced polymer (GFRP) composites, e.g. thickness of more than 50 mm, are increasingly used in a wide variety of industries, particularly in the marine and wind energy sectors. Defect detection and characterisation in these composites remain appealing challenges due to the material complexity and the presence of various manufacturing and in-service defects. In this study, we propose a novel shearography method with controlled surface temperature (CST) heating for deep defect detection (i.e., 15 mm depth and more) in thick GFRP laminates. The proposed CST heating has been developed based on analytical solutions to control the maximum surface temperature of a test object during shearography inspection. Numerical and experimental studies have been performed to analyse the defect behaviour and defect detection under various heating scenarios, a topic which is rarely reported for thick composites with shearography. Compared with conventional shearography, the CST shearography method maximises heating energy input with a controlled and stable maximum surface temperature for deep defect detection. Results indicate an enhancement of about 27% in defect signal for the defect at 15 mm depth in comparison to conventional heating. The results also provide insight for implementing an efficient inspection in terms of the inspection duration and the number of datasets. This study makes a step towards safe, quantitative and predictable inspection of deep defects in thick composites. ; Structural Integrity & Composites