People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Töyräs, Juha
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (28/28 displayed)
- 2023Broadband scattering properties of articular cartilage zones and their relationship with the heterogenous structure of articular cartilage extracellular matrixcitations
- 2021Infrared fiber-optic spectroscopy detects bovine articular cartilage degenerationcitations
- 2020Comparison of water, hydroxyproline, uronic acid and elastin contents of bovine knee ligaments and patellar tendon and their relationships with biomechanical propertiescitations
- 2019T2* and quantitative susceptibility mapping in an equine model of post-traumatic osteoarthritis: assessment of mechanical and structural properties of articular cartilage
- 2019T2* and quantitative susceptibility mapping in an equine model of post-traumatic osteoarthritis: assessment of mechanical and structural properties of articular cartilagecitations
- 2019Arthroscopic determination of cartilage proteoglycan content and collagen network structure with near-infrared spectroscopycitations
- 2019Effects of body mass on microstructural features of the osteochondral unit: A comparative analysis of 37 mammalian speciescitations
- 2018Quantitative susceptibility mapping of articular cartilage: ex vivo findings at multiple orientations and following different degradation treatmentscitations
- 2017Contrast-enhanced computed tomography enables quantitative evaluation of tissue properties at intrajoint regions in cadaveric knee cartilagecitations
- 2017Corrigendum to “Multimodality scoring of chondral injuries in the equine fetlock joint ex vivo” [Osteoarthritis Cartilage 25 (5) (2017 May) 790–798] (S1063458416304666), (10.1016/j.joca.2016.12.007))citations
- 2017Tissue viscoelasticity is related to tissue composition but may not fully predict the apparent-level viscoelasticity in human trabecular bone – an experimental and finite element studycitations
- 2016Differences in acoustic impedance of fresh and embedded human trabecular bone samples - scanning acoustic microscopy and numerical evaluationcitations
- 2015Ultrasound backscattering is anisotropic in bovine articular cartilagecitations
- 2015Inter-individual changes in cortical bone three-dimensional microstructure and elastic coefficient have opposite effects on radial sound speedcitations
- 2014Deformation of articular cartilage during static loading of a knee joint - experimental and finite element analysiscitations
- 2013New disposable forehead electrode set with excellent signal quality and imaging compatibilitycitations
- 2007Effect of human trabecular bone composition on its electrical propertiescitations
- 2006Interrelationships between electrical properties and microstructure of human trabecular bonecitations
- 2006T2 relaxation time mapping reveals age- and species-related diversity of collagen network architecture in articular cartilagecitations
- 2006Collagen network primarily controls poisson's ratio of bovine articular cartilage in compressioncitations
- 2005Prediction of mechanical properties of human trabecular bone by electrical measurementscitations
- 2005Improvement of arthroscopic cartilage stiffness probe using amorphous diamond coatingcitations
- 2004Prediction of biomechanical properties of articular cartilage with quantitative magnetic resonance imagingcitations
- 2003Structure-function relationships in enzymatically modified articular cartilagecitations
- 2003Electrical and dielectric properties of bovine trabecular bone - Relationships with mechanical properties and mineral densitycitations
- 2002Ultrasonic characterization of articular cartilage
- 2002Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentationcitations
- 2000Quantitative MR microscopy of enzymatically degraded articular cartilage
Places of action
Organizations | Location | People |
---|
article
Effect of human trabecular bone composition on its electrical properties
Abstract
Mechanical properties of bone are determined not only by bone mineral density (BMD), but also by tissue trabecular structure and organic composition. Impedance spectroscopy has shown potential to diagnose trabecular bone BMD and strength, however, the relationships between organic composition and electrical and dielectric properties have not been systematically investigated. To investigate these issues organic composition of 26 human trabecular bone samples harvested from the distal femur and proximal tibia was determined and compared with relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor measured at wide range (50 Hz to 5 MHz) of frequencies. A strong linear correlation was found between the relative permittivity at 1.2 MHz and trabecular bone fat content (r = -0.85, p < 0.01, n = 26). On the other hand, relative permittivity measured at 200 Hz served as a good predictor of water content (r = 0.83). Phase angle, specific impedance and especially conductivity were strongly related to the trabecular bone dry density and water content (|r| ≥ 0.69). Variation in bone tissue collagen content was strongly related to the relative permittivity measured at 1.2 MHz (r = 0.64), but only moderately to other parameters. Glycosaminoglycan content showed no significant relations with any investigated electrical parameters. The present study indicates that if the trabecular bone composition is known, the relationships presented in this study could facilitate calculation of current field distribution, e.g. during electrical stimulation of osteogenesis. On the other hand, our results suggest that permittivity measured at low (<1 kHz) or high (>100 kHz) frequencies could be used, e.g. during implant surgery, for prediction of trabecular bone water or fat contents, respectively.