People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Cherukuri, Rahul
Tampere University
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2024Tribological behavior and biocompatibility of novel Nickel-Free stainless steel manufactured via laser powder bed fusion for biomedical applicationscitations
- 2024In-situ SEM micropillar compression and nanoindentation testing of SU-8 polymer up to 1000 s−1 strain ratecitations
- 2024Correlated high throughput nanoindentation mapping and microstructural characterization of wire and arc additively manufactured 2205 duplex stainless steelcitations
- 2018Thermophysical and Mechanical Properties of Advanced Single Crystalline Co-base Superalloyscitations
Places of action
Organizations | Location | People |
---|
article
Tribological behavior and biocompatibility of novel Nickel-Free stainless steel manufactured via laser powder bed fusion for biomedical applications
Abstract
Due to the risk of releasing carcinogenic nickel ions from conventional 316L stainless steel under a corrosive human body environment, a new variant of steel termed nickel-free stainless steel (NiFSS) has been investigated. The present study investigates the tribological properties and biocompatibility of NiFSS manufactured via laser powder bed fusion (PBF-LB/M). The ferritic NiFSS exhibited significantly lower coefficient of friction (0.08 to 0.28) and wear rate (1.60 × 10-6 mm3/Nm to 6.60 × 10-6 mm3/Nm) compared to reported values for austenitic 316L SS, under both dry and simulated body fluid (SBF) conditions and various sliding geometries. This improvement is attributed to the superior hardness (3.394 ± 0.1340 GPa) and elastic modulus (238 ± 9.0797 GPa) of NiFSS. To assess the biocompatibility, the viability of mouse pre-osteoblastic MC3T3-E1 cells was evaluated with an Alamar Blue assay when the cells were cultured on top of PBF-LB/M built NiFSS and 316L SS samples. The results indicated that even though cell growth was most optimal on regular cell culture plastic, cell viability was better maintained on PBF-LB/M built NiFSS compared to 316L SS. Therefore, the results of the present study propose that PBF-LB/M fabricated NiFSS holds promise for application in biomedical devices for joint arthroplasty. ; Peer reviewed