Publications (14/14 displayed)
- 2021Rare-Earth-Modified Titania Nanoparticles : Molecular Insight into Synthesis and Photochemical Propertiescitations
- 2020In-process calibration of a non-destructive testing system used for in-process inspection of multi-pass weldingcitations
- 2020Laser-assisted surface adaptive ultrasound (SAUL) inspection of samples with complex surface profiles using a phased array roller-probe
- 2019Impedance Spectroscopy Modeling of Nickel–Molybdenum Alloys on Porous and Flat Substrates for Applications in Water Splittingcitations
- 2018Linear ultrasonic array design using cantor set fractal geometrycitations
- 2018Broadband 1-3 piezoelectric composite transducer design using Sierpinski Gasket fractal geometrycitations
- 2018Cation/Anion-based electrochemical degradation and rejuvenation of electrochromic nickel oxide filmscitations
- 2018MicroRNA detection based on duplex-specific nuclease-assisted target recycling and gold nanoparticle/graphene oxide nanocomposite-mediated electrocatalytic amplificationcitations
- 2018Broadband piezocrystal transducer array for non-destructive evaluation imaging applicationscitations
- 2017Linear ultrasonic array incorporating a Cantor Set fractal element configuration
- 2016Improving the operational bandwidth of a 1-3 piezoelectric composite transducer using Sierpinski Gasket fractal geometry
- 201415 MHz single element ultrasound needle transducers for neurosurgical applicationscitations
- 2012New piezocrystal material in the development of a 96-element array transducer for MR-guided focused ultrasound surgerycitations
- 2011Characterization of piezocrystals for practical configurations with temperature- and pressure-dependent electrical impedance spectroscopycitations
Places of action
Organizations | Location | People |
---|
article
In-process calibration of a non-destructive testing system used for in-process inspection of multi-pass welding
Abstract
In multi-pass welding, there is increasing motivation to move towards in-process defect detection to enable real-time repair; thus avoiding deposition of more layers over a defective weld pass. All defect detection techniques require a consistent and repeatable approach to calibration to ensure that measured defect sizing is accurate. Conventional approaches to calibration employ fixed test blocks with known defect sizes, however, this methodology can lead to incorrect sizing when considering complex geometries, materials with challenging microstructure, and the significant thermal gradients present in materials during the inter-pass inspection period. To circumvent these challenges, the authors present a novel approach to calibration and introduce the concept of in-process calibration applied to ultrasonic Non-Destructive Testing (NDT). The new concept is centred around the manufacturing of a second duplication sample, containing intentionally-embedded tungsten inclusions, with identical process parameters as the main sample. Both samples are then inspected using a high-temperature robotic NDT process to allow direct comparative measurements to be established between the real part and the calibration sample. It is demonstrated that in-process weld defect detection using the in-process calibration technique can more reliably identify defects in samples which would otherwise pass the acceptance test using a traditional calibration.