People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Cook, Richard
University of Southampton
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (16/16 displayed)
- 2022Effect of chromium and molybdenum increment on the crystal structure, nanoindentation and corrosion properties of cobalt based alloyscitations
- 2022Measuring the elastic modulus of soft biomaterials using nanoindentationcitations
- 2020A comparative study on the physicochemical characteristics of nanoparticles released in vivo from CoCrMo tapers and cement-stem interfaces of total hip replacements
- 2019The effects of substrate dilution on the microstructure and wear resistance of PTA Cu-Al-Fe aluminium bronze coatingscitations
- 2018The effect of micro-abrasion on enamel using abrasive slurries
- 2018Defect-free TiC/Si multi-layer electrical discharge coatingscitations
- 2017Investigation of wear and corrosion products from around explanted CoCrMo tapers
- 2017Inside a feather
- 2016Influence of the manufacturing finishing on the nano-scale wear resistance at the taper-trunnion interface in hip implants
- 2016Nano-scale wear characterization of CoCrMo biomedical alloyscitations
- 2016The importance of the film structure during self-powered Ibuprofen salicylate drug release from polypyrrole electrodeposited on AZ31 Mgcitations
- 2015Sub-surface characterisation of tribological contact zone of metal hip prosthesescitations
- 2015Microstructure characterisation of hypereutectoid aluminium bronze composite coatingcitations
- 2014The effect of large-area pulsed electron beam melting on the corrosion and microstructure of a Ti6Al4V alloycitations
- 2013Pulsed electron beam surface melting of CoCrMo alloy for biomedical applicationscitations
- 2013Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacementscitations
Places of action
Organizations | Location | People |
---|
article
Measuring the elastic modulus of soft biomaterials using nanoindentation
Abstract
The measurement of the elastic modulus of soft biomaterials via nanoindentation relies on the accurate determination of the zero-point of the tip-sample interaction on which the depth of penetration into the sample is based. Non-cantilever based nanoindentation systems were originally designed for hard materials, and therefore monitoring the zero-point contact presents a significant challenge for the characterisation of very soft biomaterials. This study investigates the ability of non-cantilever based nanoindentation to differentiate between hydrogels with elastic moduli on the order of single kiloPascals (kPa) using a bespoke soft contact protocol and low flexural stiffness of instrument. Polyethylene glycol (PEG) hydrogels were fabricated as a model system with a range of elastic moduli by varying the polymer concentration and degree of crosslinking. Elastic modulus values were calculated using the Oliver-Pharr method, Hertzian contact model, as well as a viscoelastic model to account for the time-dependent behaviour of the gels. The stiffness measurements were validated by measuring cantilever beams with the equivalent flexural stiffness to that of the PEG hydrogels being tested. The results demonstrated a high repeatability of the measurements, enabling differentiation between hydrogels with elastic moduli in the single kPa to hundreds of kPa range.